5. Check
5.1
Thermistor Resistance Check
Check No.01
Disconnect the connectors of the thermistors from the PCB, and measure the resistance of
each thermistor using a tester.
The relationship between normal temperature and resistance is shown in the table and the
graphs below.
For models in which the thermistor is directly mounted on the PCB, disconnect the connector
for the PCB and measure.
Thermistor temperature (°C)
Resistance (k
Ω
)
Room temperature thermistor
Other thermistors
–20
73.4
211.0
–15
57.0
150.0
–10
44.7
116.5
–5
35.3
88.0
0
28.2
67.2
5
22.6
51.9
10
18.3
40.0
15
14.8
31.8
20
12.1
25.0
25
10.0
20.0
30
8.2
16.0
35
6.9
13.0
40
5.8
10.6
45
4.9
8.7
50
4.1
7.2
(R25°C = 10 k
Ω
, B = 3435 K)
(R25°C = 20 k
Ω
, B = 3950 K)
(11952)
Other thermistors
Room temperature thermistor
(˚C)
(˚C)
50
25
0
–15
0
15
30
45
(k
Ω
)
(k
Ω
)
–15
0
15
30
45
150
100
50
Tester
Resistance range
(R11906)
RTH1
Tester
(R3460)
Содержание FTXN25KEV1B
Страница 11: ...SiBE041102_A List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 13: ...SiBE041102_A Specifications 3 Part 2 Specifications 1 Specifications 4...
Страница 109: ...SiBE041102_A Indoor Unit Removal Procedure 99 5 Remove the horizontal blade Step Procedure Points R11626...
Страница 157: ...Revision History Month Year Version Revised contents 03 2011 SiBE041102 06 2011 SiBE041102_A Review of contents...