![Daikin FTXN25KEV1B Скачать руководство пользователя страница 75](http://html2.mh-extra.com/html/daikin/ftxn25kev1b/ftxn25kev1b_service-manual_4700136075.webp)
SiBE041102_A
Troubleshooting
Service Diagnosis
65
4.10 Compressor Lock
Remote
Controller
Display
E6
Method of
Malfunction
Detection
A compressor lock is detected by the current waveform generated when applying high-
frequency voltage to the motor.
Malfunction
Decision
Conditions
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 11 minutes without any other error
Supposed
Causes
Compressor locked
Disconnection of compressor harness
Troubleshooting
Check No.15
Refer to P.91
Turn off the power. Disconnect the
harnesses U, V, and W.
(R14439)
Caution
NO
YES
YES
NO
NO
YES
Check No.15
Check with the inverter checker (
∗
).
Turn off the power and reconnect
the harnesses. Turn on the power
again and restart the system.
Correct the power supply or
replace the outdoor unit
PCB.
∗
Inverter checker
Part No.: 1225477
Replace the compressor.
Replace the compressor.
Check the electronic
expansion valve.
Replace it as required.
Normal?
Emergency
stop without compressor
running?
System shut
down after errors repeated
several times?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
(Precaution before turning on the power again)
Make sure the power has been off for at least 30 seconds.
Содержание FTXN25KEV1B
Страница 11: ...SiBE041102_A List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 13: ...SiBE041102_A Specifications 3 Part 2 Specifications 1 Specifications 4...
Страница 109: ...SiBE041102_A Indoor Unit Removal Procedure 99 5 Remove the horizontal blade Step Procedure Points R11626...
Страница 157: ...Revision History Month Year Version Revised contents 03 2011 SiBE041102 06 2011 SiBE041102_A Review of contents...