Si04-402A
Wiring Diagrams
Appendix
179
2.
Wiring Diagrams
FTXG25/35CVMAW(S), FTXG25/35CVMBW(S), ATXG25/35CVMB
RXG25/35CVMA, RXG25/35CVMB, ARXG25/35CVMB
PCB3
EYE SENSOR
INTELLIGENT-
CONTROLLER
WIRELESS
R1T
REMOTE
t
S36
˚
S36
PCB1
3
2
1
1
S21
HA
S32
PCB2
RECEIVER
S2W
1
1
SIGNAL
S51
2
BLK
WHT
S47
S46
1
LED4
RED
H4P
M1S
M
ORG
YL
W
LED3
H3P
12
PNK
S41
12
5
BLU
6
RED
M2S
LED2
M
H2P
ORG
YL
W
~
PNK
10
RECTIFIER
TRANSMISSION
BLU
1
CIRCUIT
RED
M3S
S1W
S49
M
ORG
~
YL
W
PNK
5
R2T
BLU
t ˚
1
WHT
M1F
S1
M
ORG
H3
H2
4
BRN
BLU
FU
7
RED
H1B
3.15A
FG
indoor
E1
GRN/YLW
GRN/YLW
E2
FU : FUSE
FG : FLAME GRUND
E1 : EARTH TERMINAL(HIELD PLATE)
E2 : EARTH TERMINAL(HEAT. EX)
R1T, R2T : THERMISTOR
M1F : FAN MOTOR
H2P~H4P : PILOT LAMP
H1B, H2, H3 : HARNESS
S1~S51 : CONNECTOR
X1M : TERMINAL STRIP
S2W : PANEL LIMIT SWITCH
S1W : OPERATION SWITCH
M1S, M2S, M3S : SWING MOTOR
WHT
BLK
RED
PCB1, PCB2, PCB3 : PRINTED CIRCUIT BOARD
X1M
3
2
1
: PROTECTIVE EARTH
ON AGAIN.
THE MAIN POWER SUPPLY IS
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
TURNED OFF AND THEN BACK
FIELD WIRING.
CAUTION
2
3
1
3D044813B
1
outdoor
NOTE
N
MRCW, MRM10, MRM20 : MAGNETIC RELAY
L
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
indoor
L
: LIVE
IPM1
: INTELLIGENT POWER MODULE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
C74, C75
IC11
: TRIAC
DB1, DB2
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
C94, C95, C100
: CAPACITOR
3
2
1
FIELD WIRING.
L
N
X1M
2
3
1
RED
BLK
WHT
GRN/YL
W
Z2C
GRN/YL
W
HN1
HL1
E
S
FU3
20A
V2
PCB1
V3
N
: NEUTRAL
SA1
Q1L
: OVERLOAD PROTECTOR
PCB1, PCB2
: PRINTED CIRCUIT BOARD
R1T, R2T, R3T
: THERMISTOR
S30, S40, S70
HC3, HC4, HL3, HN3 : CONNECTOR
S80, S90, S91
S10, S11, S20
L1
outdoor
S80
TYPE
COOLING ONLY
IN CASE OF
HC2
1
C100
MRM10
MRM20
7
1
HC1
3
S11
WHT
BLK
BLK
BLK
BLK
BLK
BLK
HR1
HN2
HL2
ORG
GRY
BLU
1
7
1
ORG
S10
RED
S20
M
YL
W
BLK
L1R
Y1E
GR
Y
6
SA1
: SURGE ARRESTER
V1, V2, V3
: VARISTOR
Y1E
: ELECTRONIC EXPANSION VALVE COIL
Y1R
: REVERSING SOLENOIDE VALVE COIL
X1M
: TERMINAL STRIP
Z1C, Z2C
: FERRITE CORE
WHT
3.15A
MRCW
S80
HL3
FU1
HN3
TYPE
HEAT PUMP
IN CASE OF
YLW
BRN
ORG
1
Y1R
V1
: PROTECTIVE EARTH
HR2
3
(OUTDOOR)
~
~
DB1
IC11
+
-
PCB2
R1T
1
(CONDENSER)
BLK
t˚
BLK
S90
HC3
R2T
~
~
BLK
DB2
t˚
+
-
BLK
(DISCHARGE)
R3T
BLK
6
t˚
BLK
S70
C75
C74
1
HC4
WHT
2
ORG
1
+
-
-
+
3
M
~
BRN
4
M1F
BLU
+
-
+
-
C94
3.15A
7
FU2
RED
C95
2
Q1L
S40
BLK
GR
Y
1
S30
3D042576E
W
+
W
-
5
BLU
M1C
IPM1
V
V
3
YL
W
U
1
U
N=2
Z1C
RED
Содержание FTXG25CVMAW
Страница 1: ...Inverter Pair Wall Mounted Type C Series Applied Models z z z zInverter Pair Heat Pump Si04 402A...
Страница 23: ...Printed Circuit Board Connector Wiring Diagram Si04 402A 14 Printed Circuit Board Connector Wiring Diagram...
Страница 167: ...Outdoor Unit Si04 402A 158 Removal Procedure When reassembling make sure to fit the hook Step Procedure Points...
Страница 181: ...Outdoor Unit Si04 402A 172 Removal Procedure...
Страница 185: ...Others Si04 402A 176 Others...
Страница 189: ...Wiring Diagrams Si04 402A 180 Appendix...