English
12
To change the temperature setting
Press .
The displayed items on the LCD will change whenever either one of the buttons is
•
pressed.
COOL operation
HEAT operation
AUTO operation
DRY or FAN operation
18-32°C
10-30°C
18-30°C
The temperature setting is
not variable.
Press
to raise the temperature and press
to lower the
temperature.
Operating conditions
Recommended temperature setting
For cooling: 26-28°C
•
For heating: 20-24°C
•
Tips for saving energy
Be careful not to cool (heat) the room too much.
•
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
•
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air
fi
lters cause inef
fi
cient operation and waste energy. Clean them once in about every 2 weeks.
•
Notes on the operating conditions
The air conditioner always consumes a small amount of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker.
•
Use the air conditioner in the following conditions.
•
Operation outside the humidity or temperature range described in the table may cause a safety device to disable the system.
•
MODE
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature : <2/3/4/5MXS> –10-46°C
<RXG> –10-46°C
Indoor temperature : 18-32°C
Indoor humidity : 80% max.
A safety device may work to stop the operation.
•
(In multi system, it may work to stop the operation of the
outdoor unit only.)
Condensation may occur on the indoor unit and drip.
•
HEAT
Outdoor temperature : <2MXS> –10-24°C
<3/4/5MXS> –15-24°C
<RXG> –15-24°C
Indoor temperature : 10-30°C
A safety device may work to stop the operation.
•
DRY
Outdoor temperature : <2/3/4/5MXS> –10-46°C
<RXG> –10-46°C
Indoor temperature : 18-32°C
Indoor humidity : 80% max.
A safety device may work to stop the operation.
•
Condensation may occur on the indoor unit and drip.
•
01_EN_3P357704-1.indd 12
01_EN_3P357704-1.indd 12
12/17/2013 3:22:02 PM