Français
40
LED DE LA CARTE À CIRCUIT IMPRIMÉ DE L’UNITÉ EXTÉRIEURE
Séries 3MXS, 4MXS, 5MXS
VERT
ROUGE
MICROORDINATEUR
NORMAL
DÉTECTION DE
DYSFONCTIONNEMENT
LED-A
LED1 LED2 LED3 LED4 LED5
DIAGNOSTIC
●
●
●
●
●
NORMAL VÉRIFIEZ L’UNITÉ INTÉRIEURE
●
●
DISPOSITIF DE PROTECTION CONTRE LA HAUTE PRESSION ACTIVÉ
OU GEL DANS L’UNITÉ EN FONCTION OU DANS L’UNITÉ EN ATTENTE
●
●
●
∗
RELAIS DE SURCHARGE ACTIVÉ OU HAUTE TEMPÉRATURE
DE TUYAU DE DÉCHARGE
●
●
●
DÉMARRAGE DU COMPRESSEUR DÉFECTUEUX
●
●
●
SURINTENSITÉ D’ENTRÉE
●
●
●
∗
ANOMALIE DE THERMISTOR OU CT
●
●
HAUTE TEMPÉRATURE DU BOÎTIER DE COMMUTATION
●
●
●
●
HAUTE TEMPÉRATURE AU DISSIPATEUR DE CHALEUR DU
CIRCUIT D’INVERSEUR
●
●
●
●
∗
SURINTENSITÉ DE SORTIE
●
●
●
∗
MANQUE DE RÉFRIGERANT
●
●
●
BASSE TENSION DU CIRCUIT PRINCIPAL OU CHUTE DE
TENSION MOMENTANÉE
●
●
●
●
PANNE DE COMMUTATION D’ÉLECTROVANNE D’INVERSION
●
ANOMALIE DU MOTEUR DE VENTILATEUR
−
−
−
−
●
[REMARQUE 1]
●
−
−
−
−
●
ANOMALIE D’ALIMENTATION ÉLECTRIQUE OU [REMARQUE 2]
REMARQUE: La LED 5 est disponible seulement pour la série 5M.
VERT
CLIGNOTE NORMALEMENT
ROUGE
ÉTEINT NORMALEMENT
OALLUMÉ
CLIGNOTE
●
ÉTEINT
−
SANS RAPPORT
LED DE LA CARTE À CIRCUIT IMPRIMÉ DE L’UNITÉ EXTÉRIEURE
Série 2MXS
VERT
MICROORDINATEUR NORMAL
LED-A
DIAGNOSTIC
NORMAL VÉRIFIEZ L’UNITÉ INTÉRIEURE
[REMARQUE 1]
●
ANOMALIE D’ALIMENTATION ÉLECTRIQUE OU [REMARQUE 2]
VERT CLIGNOTE NORMALEMENT
OALLUMÉ
CLIGNOTE
●
ÉTEINT
REMARQUE
Mettez l’alimentation électrique sur arrêt puis à nouveau sur marche. Si l’af
fi
chage de la LED réapparaît, la carte à circuit imprimé de l’unité
•
extérieure est défectueuse.
Diagnostic marqué
•
∗
N’est pas applicable dans certains cas. Pour plus de détails, reportez-vous au guide de service.
03_FR_3P357704-1.indd 40
03_FR_3P357704-1.indd 40
12/17/2013 3:25:19 PM
12/17/2013 3:25:19 PM