background image

• Indoor Unit • FTXG-LS, FTXG-LW

1

• Split - Sky Air • FTXG-LS, FTXG-LW

2

1

Features

1 - 1

FTXG-LS

I

n

d

o

o

r

 

U

n

i

t

Remarkable blend of iconic design and engineering excellence with 
an elegant finish in silver and anthracite

Daikin Emura has been awarded with Reddot design award 2014 by 
an international jury, thanks to its excellent design

Designed to perfectly balance technological leadership and the 
beauty of aerodynamics

Seasonal efficiency values up to A+++

Online controller (optional): control your indoor from any location with 
an app, via your local network or internet

Whisper quiet in operation: the operating of the unit can hardly be 
heard.  The sound pressure level goes down to 19dBA!

Econo mode

2 area 

intelligent eye

Energy saving 

during standby 

mode

Night set mode

Fan only

Comfort mode Powerful mode Auto cooling-

heating 

changeover

Whisper quiet

Indoor unit 

silent operation

3-D air flow

Vertical auto 

swing

Horizontal auto 

swing

Auto fan speed

Fan speed 

steps

Dry programmeTitanium apatite 

photocatalytic 

air purification 

filter

Weekly timer

24 hour timer Infrared remote 

control

Wired remote 

control

Centralised 

control

Online 

controller via 

app

Auto-restart

Self diagnosis

Multi model 

application

VRV for 

residential 

application

Содержание FTXG20LS

Страница 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN15 100 FTXG LS FTXG LW ...

Страница 2: ......

Страница 3: ...FTXG LW 1 Features 2 FTXG LS 2 FTXG LW 3 2 Specifications 4 Technical Specifications 4 Electrical Specifications 5 3 Options 6 4 Dimensional drawings 7 5 Centre of gravity 8 6 Piping diagrams 9 7 Wiring diagrams 11 Wiring Diagrams Single Phase 11 8 Sound data 12 Sound Pressure Spectrum 12 ...

Страница 4: ...on with an app via your local network or internet Whisper quiet in operation the operating of the unit can hardly be heard The sound pressure level goes down to 19dBA Econo mode 2 area intelligent eye Energy saving during standby mode Night set mode Fan only Comfort mode Powerful mode Auto cooling heating changeover Whisper quiet Indoor unit silent operation 3 D air flow Vertical auto swing Horizo...

Страница 5: ...app via your local network or internet Whisper quiet in operation the operating of the unit can hardly be heard The sound pressure level goes down to 19dBA Econo mode 2 area intelligent eye Energy saving during standby mode Night set mode Fan only Comfort mode Powerful mode Auto cooling heating changeover Whisper quiet Indoor unit silent operation 3 D air flow Vertical auto swing Horizontal auto s...

Страница 6: ...ti on m min 2 6 2 9 3 6 2 6 2 9 3 6 cfm 91 102 128 91 102 128 Heating High m min 10 2 11 0 12 4 12 6 10 2 11 0 12 4 12 6 cfm 361 388 438 446 361 388 438 446 Nom m min 8 4 8 6 9 6 10 5 8 4 8 6 9 6 10 5 cfm 298 303 340 372 298 303 340 372 Low m min 6 3 6 9 8 1 6 3 6 9 8 1 cfm 223 245 284 223 245 284 Silent operati on m min 3 8 4 1 5 0 3 8 4 1 5 0 cfm 133 144 176 133 144 176 Fan motor Model KFD 280 4...

Страница 7: ...ions of the multi outdoor unit to be connected Refrigerant Type R 410A Piping connections Liquid OD 6 35 Gas OD 9 5 12 7 9 5 12 7 Drain 18 Heat insulation Both liquid and gas pipes Temperature control Microcomputer control Air direction control Right Left Horizontal Downward 2 2 Electrical Specifications FTXG20LS FTXG25LS FTXG35LS FTXG50LS FTXG20LW FTXG25LW FTXG35LW FTXG50LW Power supply Name V1 P...

Страница 8: ... Indoor Unit FTXG LS FTXG LW 3 Split Sky Air FTXG LS FTXG LW 6 3 Options 3 1 Options ...

Страница 9: ...3 4 Split Sky Air FTXG LS FTXG LW 7 Indoor Unit FTXG LS FTXG LW 4 Dimensional drawings 4 1 Dimensional Drawings ...

Страница 10: ... Indoor Unit FTXG LS FTXG LW 5 Split Sky Air FTXG LS FTXG LW 8 5 Centre of gravity 5 1 Centre of Gravity 㻡㻟㻢㻚㻡 㻝㻢㻟㻚㻣 㻥㻥㻣㻚㻤 㻢㻜㻚㻟 㻡㻟㻢㻚㻡 㻟㻜㻝㻚㻤 7 6 ...

Страница 11: ...FTXG LW 9 Indoor Unit FTXG LS FTXG LW 6 Piping diagrams 6 1 Piping Diagrams 6 4CuT M 6 4CuT 9 5CuT 9 5CuT URVVIORZ IDQ HDW H FKDQJHU HDW H FKDQJHU WKHUPLVWRU DQ PRWRU LHOG SLSLQJ LHOG SLSLQJ 5HIULJHUDQW IORZ RROLQJ HDWLQJ 㻌 7 6 ...

Страница 12: ... Indoor Unit FTXG LS FTXG LW 6 Split Sky Air FTXG LS FTXG LW 10 6 Piping diagrams 6 1 Piping Diagrams ...

Страница 13: ... RORXUV 3LQN 到 5 65 51 51 75 6 3 6 6 6 6 5 25 8 6 3 6 6 6 3 5 7 Wr 6 3 3 6 7 5 0 8 05 8 9 7 25 51 8 5 6 0 0 6 5 7 0 6 0 6 0 6 06 06 06 Wr 6 6 6 6 5 25 31 8 5 25 31 8 5 25 31 8 0 0 2XWGRRU QGRRU UDPH JURXQG XVH 3LORW ODPS DQ PRWRU 6ZLQJ PRWRU 6WHSSHU PRWRU 3ULQWHG FLUFXLW ERDUG 7KHUPLVWRU RQQHFWRU 2SHUDWLRQ VZLWFK 7HUPLQDO VWULS X HU 3URWHFWLYH HDUWK 7UDQVPLVVLRQ FLUFXLW LUHOHVV UHPRWH FRQWURO QWHO...

Страница 14: ...ĞƚŚŽĚ ŝƐ ŝŶ ĂĐĐŽƌĚĂŶĐĞ ǁŝƚŚ ϵϲϭϮ ĂĐŬŐƌŽƵŶĚ ŶŽŝƐĞ ĂůƌĞĂĚLJ ƚĂŬĞŶ ŝŶƚŽ ĂĐĐŽƵŶƚ dŽƚĂů Ě dŽƚĂů Ě ĂĐŬŐƌŽƵŶĚ ŶŽŝƐĞ ĂůƌĞĂĚLJ ƚĂŬĞŶ ŝŶƚŽ ĂĐĐŽƵŶƚ dy Ϯϱ t ϯ ϬϴϲϴϰϮ Ϯϴ ϯϴ Ϯϱ ϰϭ EŽƚĞƐ ŽĐĂƚŝŽŶ ŽĨ ŵŝĐƌŽƉŚŽŶĞ DĞĂƐƵƌŝŶŐ ůŽĐĂƚŝŽŶ ĂŶĞĐŚŽŝĐ ĐŚĂŵďĞƌ ĐĂůĞ Ě с ͲǁĞŝŐŚƚĞĚ ƐŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů ƐĐĂůĞ ĂĐĐŽƌĚŝŶŐ ƚŽ Ϳ Ě Ě KĐƚĂǀĞ ďĂŶĚ ĐĞŶƚƌĞ ĨƌĞƋƵĞŶĐLJ nj ŽŽůŝŶŐ ŵŽĚĞ ŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů Ě ŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů Ě ĞĂƚŝŶŐ ŵŽĚĞ ĞŐĞŶĚ KĐ...

Страница 15: ...ƚŝŽŶƐ ƉŽǁĞƌ ƐŽƵƌĐĞ ϮϮϬͲϮϰϬ s ϮϮϬ s ϱϬ ϲϬ nj ƐƚĂŶĚĂƌĚ ĂĐŬŐƌŽƵŶĚ ŶŽŝƐĞ ĂůƌĞĂĚLJ ƚĂŬĞŶ ŝŶƚŽ ĂĐĐŽƵŶƚ dŽƚĂů Ě dŽƚĂů Ě ĂĐŬŐƌŽƵŶĚ ŶŽŝƐĞ ĂůƌĞĂĚLJ ƚĂŬĞŶ ŝŶƚŽ ĂĐĐŽƵŶƚ dy ϱϬ t ϯ Ϭϴϲϴϰϯ ϯϱ ϰϲ ϯϱ ϰϳ ŽĐĂƚŝŽŶ ŽĨ ŵŝĐƌŽƉŚŽŶĞ DĞĂƐƵƌŝŶŐ ůŽĐĂƚŝŽŶ ĂŶĞĐŚŽŝĐ ĐŚĂŵďĞƌ ĐĂůĞ Ě с ͲǁĞŝŐŚƚĞĚ ƐŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů ƐĐĂůĞ ĂĐĐŽƌĚŝŶŐ ƚŽ Ϳ Ě Ě KĐƚĂǀĞ ďĂŶĚ ĐĞŶƚƌĞ ĨƌĞƋƵĞŶĐLJ nj ŽŽůŝŶŐ ŵŽĚĞ ŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů Ě ŽƵŶĚ ƉƌĞƐƐƵƌĞ ůĞǀĞů Ě ĞĂƚŝŶŐ ...

Страница 16: ......

Страница 17: ...kin Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose of its content and the products and services presented therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect...

Отзывы: