Troubleshooting
SiBE041012_B
98
Service Diagnosis
Troubleshooting
25/35 class, RXG50K3V1B
Check No.15
Refer to P.114
Check No.18
Refer to P.117
Check No.20
Refer to P.118
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
NO
YES
Turn off the power.
Check the connection.
Check the power supply voltage.
Correct the power supply.
Voltage as rated?
(R18319)
NO
NO
NO
YES
YES
NO
YES
YES
Check No. 20
Check the short circuit of the diode
bridge.
Check No.15
Check with the inverter analyzer.
Turn off the power. Disconnect the
harnesses U, V, and W.
Turn on the power.
Check the electrolytic capacitor
voltage.
Electrical
components or
compressor harnesses
connected as
specified?
Replace the outdoor unit
PCB.
Replace the compressor.
Correct the power supply
or replace the outdoor unit
PCB.
Reconnect the electrical
components or compressor
harnesses as specified.
Replace the outdoor unit
PCB.
∗
Inverter analyzer:
RSUK0917C
Normal?
NO
YES
Check No. 18
Check the discharge pressure.
Replace the stop valve.
OK?
320 ± 50 VDC?
Any LED OFF?
Содержание FTXG-J
Страница 11: ...SiBE041012_B List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiBE041012_B Specifications 5 Part 2 Specifications 1 Specifications 6 ...
Страница 68: ...SiBE041012_B 58 Remote Controller Part 5 Remote Controller 1 FTXG25 35 50JV1BW S A 59 ...
Страница 131: ...SiBE041012_B Check Service Diagnosis 121 RXG50K2V1B RXG50K3V1B R16073 Power module Power module R16692 ...