Table of contents

Installation Manual

3

FTXF20~42C5V1B 
Daikin room air conditioners
3P519299-9X – 2020.12

Table of contents

1 About the documentation

3

1.1

About this document..................................................................

3

2 Specific installer safety instructions

3

3 About the box

5

3.1

Indoor unit .................................................................................

5

3.1.1

To remove the accessories from the indoor unit.........

5

4 About the unit

5

4.1

System layout ............................................................................

5

4.2

Operation range ........................................................................

5

5 Unit installation

6

5.1

Preparing the installation site ....................................................

6

5.1.1

Installation site requirements of the indoor unit ..........

6

5.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

6

5.2

Opening the indoor unit .............................................................

6

5.2.1

To remove the front panel...........................................

6

5.2.2

To re-install the front panel .........................................

6

5.2.3

To remove the front grille ............................................

6

5.2.4

To re-install the front grille ..........................................

7

5.2.5

To remove the electrical wiring box cover...................

7

5.2.6

To open the service cover...........................................

7

5.3

Mounting the indoor unit............................................................

7

5.3.1

To install the mounting plate .......................................

7

5.3.2

To drill a wall hole .......................................................

7

5.3.3

To remove the pipe port cover ....................................

8

5.3.4

To provide drainage ....................................................

8

6 Piping installation

9

6.1

Preparing refrigerant piping .......................................................

9

6.1.1

Refrigerant piping requirements..................................

9

6.1.2

Refrigerant piping insulation .......................................

9

6.2

Connecting the refrigerant piping ..............................................

9

6.2.1

Guidelines when connecting the refrigerant piping ..... 10

6.2.2

To connect the refrigerant piping to the indoor unit .... 10

6.3

Checking the refrigerant piping .................................................

10

6.3.1

To check for leaks....................................................... 10

6.3.2

To perform vacuum drying .......................................... 10

7 Electrical installation

10

7.1

Specifications of standard wiring components ..........................

11

7.2

To connect the electrical wiring to the indoor unit .....................

11

8 Finishing the indoor unit installation

11

8.1

To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................

11

8.2

To pass the pipes through the wall hole....................................

12

8.3

To fix the unit on the mounting plate .........................................

12

9 Configuration

12

9.1

To set a different address..........................................................

12

10 Commissioning

13

10.1

Checklist before commissioning ................................................

13

10.2

Checklist during commissioning ................................................

13

10.3

To perform a test run .................................................................

13

10.3.1

To perform a test run in winter season ....................... 14

11 Disposal

14

12 Technical data

15

12.1

Wiring diagram ..........................................................................

15

12.1.1

Unified wiring diagram legend..................................... 15

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

INFORMATION

This  document  only  describes  installation  instructions
specific  to  the  outdoor  unit.  For  installation  of  the  indoor
unit  (mounting  the  indoor  unit,  connecting  the  refrigerant
piping to the indoor unit, connecting the electrical wiring to
the indoor unit …), see the installation manual of the indoor
unit.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Содержание FTXF20C5V1B

Страница 1: ...Installation Manual Daikin room air conditioners English Installation Manual Daikin room air conditioners FTXF20C5V1B FTXF25C5V1B FTXF35C5V1B FTXF42C5V1B...

Страница 2: ...vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumiem atbils...

Страница 3: ...m a test run in winter season 14 11 Disposal 14 12 Technical data 15 12 1 Wiring diagram 15 12 1 1 Unified wiring diagram legend 15 1 About the documentation 1 1 About this document INFORMATION Make s...

Страница 4: ...ay cause refrigerant gas leakage CAUTION Do NOT open the valves before flaring is complete This would cause refrigerant gas leakage DANGER RISK OF EXPLOSION Do NOT start the unit if it is vacuumed Cha...

Страница 5: ...witch box cover before turning on the power supply Commissioning see 10 Commissioning 413 DANGER RISK OF ELECTROCUTION DANGER RISK OF BURNING SCALDING CAUTION Do NOT perform the test operation while w...

Страница 6: ...oor and keep the following requirements in mind for distances from the walls and the ceiling 50 50 30 mm 5 1 2 Additional installation site requirements of the outdoor unit in cold climates Protect th...

Страница 7: ...the centres of the drilling points on the wall using a tape measure Position the end of tape measure at symbol 4 Finish the installation by securing the mounting plate on the wall using M4 25L screws...

Страница 8: ...a field supplied hose with inner 16 mm Do NOT forget to use a heat insulation tube on the indoor section of the extension hose a a b c 16 16 a Drain hose supplied with the indoor unit b Heat insulatio...

Страница 9: ...check for water leaks 6 Piping installation 6 1 Preparing refrigerant piping 6 1 1 Refrigerant piping requirements NOTICE The piping and other pressure containing parts shall be suitable for refriger...

Страница 10: ...ection cable d Liquid pipe e Liquid pipe insulation f Finishing tape g Drain hose NOTICE Make sure to insulate all refrigerant piping Any exposed piping might cause condensation 6 3 Checking the refri...

Страница 11: ...ning the indoor unit 46 3 Pass the interconnection cable from the outdoor unit through the feed through wall hole through the back of the indoor unit and through the front side Note In case the interc...

Страница 12: ...Note Take care that the interconnection cable does NOT get caught in the indoor unit 3 Press the bottom edge of the indoor unit with both hands until it is firmly caught by the mounting plate hooks 4...

Страница 13: ...matches the voltage on the identification label of the unit The specified wires are used for the interconnection cable The indoor unit receives the signals of the user interface There are NO loose con...

Страница 14: ...automatically restarts immediately after power is restored For FTXF ATXF CTXF units 1 Press to switch the system on 2 Press the centre of and simultaneously 3 Press twice Result will appear on the dis...

Страница 15: ...D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting diode Symb...

Страница 16: ...on Manual 16 FTXF20 42C5V1B Daikin room air conditioners 3P519299 9X 2020 12 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Ferri...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P519299 9X 2020 12 Copyright 20...

Отзывы: