English
■
4
Indoor Unit Installation Diagram
CAUTION
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
• Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units or humidifiers outside the sensor’s
detection area.
Air filter
Titanium apatite
deodorizing filter (2 pcs)
C
Titanium apatite
deodorizing filter
Filter frame
Air filter
Tab
A
Mounting plate
Mounting plate fixing
screw M4 × 1” (M4 × 25mm)
B
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
A
INTELLIGENT EYE
sensor
1-3/16” (30mm) or more
from ceiling
Wrap the insulation pipe
with the finishing tape from
bottom to top.
Cut thermal insulation pipe
to an appropriate length
and wrap it with tape,
making sure that no gap is
left in the insulation pipe’s
cut line.
Do not connect
commercially available
drain hose directly to the
indoor unit. (Water leakage
may result)
Caulk pipe hole gap
with putty.
Front panel
The service lid is removable.
Opening method
1) Remove the service lid
screw.
2) Pull out the service lid
diagonally down in the
direction of the arrow.
3) Pull down.
Service lid
1-15/16” (50mm)
or more from walls
(on both sides)
Screw
M4 × 5/8”
(M4 × 16mm)
Remote controller
holder fixing screw
M3 × 13/16”
(M3 × 20mm)
F
D Wireless
remote
controller
E Remote
controller
holder
Before screwing the
remote controller holder to
the wall, make sure that
control signals are properly
received by indoor unit.
E
Screw cover
J
A Mounting
plate
Hook
Mark (rear side)
Front
grille
Bottom frame
How to attach the indoor unit
Hook the hooks of the bottom frame
to the mounting plate.
If the hooks are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the hooks. If it is difficult
to release, remove the front grille.
A
01_EN_3P572321-1A.fm Page 4 Thursday, August 8, 2019 10:47 AM