Application Information
Additional Charge
• The refrigerant gas is charged in the outdoor unit and, if the piping length is 7.6m, additional charge of the
refrigerant after vacuuming is not necessary.
• When the piping length is more than 7.6m, additional refrigerant charge (g) per additional 1m length as
tabulated:
R410A – Cooling Only
Model
Indoor
FTN25JXV1
FTN25JXV1
FTN35JXV1
FTN35JXV1
Outdoor
RN25CJXV1
RN25FXV1
RN35CJXV1
RN35FXV1
Add. Charge, g/m
9
9
9
9
Model
Indoor
FTN50JXV1
FTN60JXV1
FTN80FXV1
Outdoor
RN50CJXV1
RN60CJXV1
RR71CXV1
RR71CXY1
Add. Charge, g/m
19
16
23
23
R410A – Heatpump
Model
Indoor
FTYN20JXV1
FTYN25JXV1
FTYN35JXV1
FTYN35JXV1
Outdoor
RYN20CGXV1
RYN25CJXV1
RYN35CJXV1
RYN35CJHXV1
Add. Charge, g/m
20
16
16
16
Model
Indoor
FTYN50JXV1
FTYN60JXV1
FTYN80FXV1
Outdoor
RYN50CJXV1
RYN60CJXV1
RQ71CXV1
RQ71CXY1
Add. Charge, g/m
19
16
41
41
Содержание FTN25JXV1
Страница 2: ......
Страница 46: ...43 Wiring Diagram Indoor Unit Model FTN50 60JXV1 Outdoor Unit Model RN50 60CJXV1...
Страница 47: ...44 Wiring Diagram Indoor Unit Model FTN80FXV1 Outdoor Unit Model RR71CXV1...
Страница 48: ...45 Wiring Diagram Indoor Unit Model FTN80FXV1 Outdoor Unit Model RR71CXY1...
Страница 49: ...46 Wiring Diagram Indoor Unit Model FTYN20JXV1 Outdoor Unit Model RYN20CGXV1...
Страница 50: ...47 Wiring Diagram Heatpump Indoor Unit Model FTYN25 35JXV1 Outdoor Unit Model RYN25 35CJXV1 RYN35CJHXV1...
Страница 51: ...48 Wiring Diagram Indoor Unit Model FTYN50 60JXV1 Outdoor Unit Model RYN50 60CJXV1...
Страница 52: ...49 Wiring Diagram Indoor Unit Model FTYN80FXV1 Outdoor Unit Model RQ71CXV1...
Страница 53: ...50 Wiring Diagram Indoor Unit Model FTYN80FXV1 Outdoor Unit Model RQ71CXY1...
Страница 62: ......