Troubleshooting
Error Code / Fault Condition
When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before
proceeding with the following troubleshooting procedures.
The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which
are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
No
Fault conditions
Possible causes / corrective actions
1
The air conditioner unit will not resume after
power failure.
• The auto restart function is not functioning.
Please turn on the unit with the wireless /
wired controller.
2
The compressor does not operate 3 minutes
after the air conditioner unit is started.
• Protection against frequent starting.
• Wait for 3 or 4 minutes for the compressor to
start operating by itself.
3
The airfl ow is too slow or room cannot be
cooled suffi ciently.
• The air fi lter is dirty.
• The doors and windows are opened.
• The air suction and discharge of both indoor
and outdoor units are clogged or blocked.
• The regulated temperature or temperature
setting is not low enough.
4
Discharge airfl ow has bad odor.
• Cigarettes, smoke particles, perfume and
others, which might have adhered onto the
coil, may cause odor.
• Contact your nearest dealer.
5
Condensation on the front air grille of the indoor
unit.
• This is caused by air humidity after an
extended period of operation.
• The set temperature is too low. Increase the
temperature setting and operate the unit at
high fan speed.
6
Water fl owing out from the air conditioner.
• Switch off the unit and contact your nearest
dealer. This might be due to tilted installation.
7
Hissing airfl ow sound from the air conditioner
unit during operation.
• Liquid refrigerant fl owing into the evaporator
coil.
8
The wireless controller display is dim.
• The batteries are discharged.
• The batteries are not correctly inserted.
• The assembly is not good.
9
Compressor operates continuously.
• Dirty air fi lter. Clean the air fi lter.
• Temperature setting too low (cooling). Use
higher temperature setting.
• Temperature setting too high (heating). Use
lower temperature setting.
10
No cool air comes out during cooling cycle, or
no hot air comes out during heating cycle.
• Temperature setting too high (cooling). Use
lower temperature setting.
• Temperature setting too low (heating). Use
higher temperature setting.
11
On heating cycle, warm air does not come out.
• Unit is in defrost mode. Heating operation will
resume after defrost cycle ends.
Содержание FTN25JXV1
Страница 2: ......
Страница 46: ...43 Wiring Diagram Indoor Unit Model FTN50 60JXV1 Outdoor Unit Model RN50 60CJXV1...
Страница 47: ...44 Wiring Diagram Indoor Unit Model FTN80FXV1 Outdoor Unit Model RR71CXV1...
Страница 48: ...45 Wiring Diagram Indoor Unit Model FTN80FXV1 Outdoor Unit Model RR71CXY1...
Страница 49: ...46 Wiring Diagram Indoor Unit Model FTYN20JXV1 Outdoor Unit Model RYN20CGXV1...
Страница 50: ...47 Wiring Diagram Heatpump Indoor Unit Model FTYN25 35JXV1 Outdoor Unit Model RYN25 35CJXV1 RYN35CJHXV1...
Страница 51: ...48 Wiring Diagram Indoor Unit Model FTYN50 60JXV1 Outdoor Unit Model RYN50 60CJXV1...
Страница 52: ...49 Wiring Diagram Indoor Unit Model FTYN80FXV1 Outdoor Unit Model RQ71CXV1...
Страница 53: ...50 Wiring Diagram Indoor Unit Model FTYN80FXV1 Outdoor Unit Model RQ71CXY1...
Страница 62: ......