Outdoor Unit
SiMT041509E
11
Printed Circuit Board Connector Wiring Diagram
2. Outdoor Unit
Main PCB
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector and high pressure switch
3) S70
Connector for DC fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) S92
Jumpers for local setting
∗
Neither disconnect the connector nor cut any of the jumpers.
7) S100
Connector for fan motor (for cooling electrical box)
8) HL1, HN1, S
Connector for terminal board
9) E1, E2
Terminal for earth wire
10) U, V, W
Connector for compressor
11) FU1, FU2
Fuse (3.15 A, 250 V)
12) FU3
Fuse (30 A, 250 V)
13) LED A
LED for service monitor (green)
14) V2, V3, V401
Varistor
V401
FU1
V2
V3 HN1
HL1
FU3
S
S40
S20
S92
S90
LED A
S100
S70
FU2
S80
U V
W
E2
E1
2P387226-1