For RK25J, RK35J, RX25J, RX35J
Si04-115
132
Removal Procedure
2.7
Removal of Four-way Valve
Procedure
Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step
Procedure
Points
1. To remove the parts
around the four-way valve.
1
Remove the terminal
cover, the lead wires of
the compressor and the
partition plate so as not
to be burnt out by a gas
brazing machine.
2
Remove the thermister
for the heat exchanger.
"
The thermister for heat
exchanger is fixed by a tie-
lap at one portion. Be sure to
fix the thermister on the
original position when
restoring.
Warning!
Ventilate when refrigerant
leaks during the work.
(If refrigerant contacts fire, it
will cause to arise toxic gas).
"
Pay attention so as not to
loose the retainer for the
thermister.
3
Remove the four-way
valve’s coil.