Daikin FLOSTO150 Скачать руководство пользователя страница 5

General safety precautions

Installation and operating instructions

5

Daikin FLOSTO150
Hot water storage tank
008.1632099_00 – 03/2019 – EN

These instructions provide all the necessary information for installa-
tion, commissioning and maintenance, as well as basic information
on operation and settings. Please see the attached documents for a
detailed description of operation and control.

Relevant documents

▪ When connecting to an external heat generator; the associated in-

stallation and operating instructions.

These instructions are included in the scope of supply for the indi-
vidual devices.

1.1.2

Meaning of warnings and symbols

Warnings in these instructions are classified according into their
severity and probability of occurrence.

DANGER

Indicates an immediate danger.

Disregarding this warning can lead to serious injury or
death

WARNING

Indicates a potentially dangerous situation

Disregarding this warning may result in serious physical in-
jury or death.

CAUTION

Indicates a situation which may cause possible damage

Disregarding this warning can cause damage to property
and the environment and result in minor injuries.

This symbol identifies user tips and particularly useful in-
formation, but not warnings or hazards

Special warning signs

Some types of danger are represented by special symbols.

Electric current

Risk of burning or scalding

Validity

Some information in these instructions has limited validity. The valid-
ity is highlighted by a symbol.

Comply with the stipulated tightening torque (see chap. )

Handling instructions

1

Handling instructions are shown as a list. Actions for which the
sequential order must be maintained are numbered.

è

Results of actions are identified with an arrow.

1.2

Safety instructions for installation
and operation

1.2.1

General

WARNING

Devices that have not been set up and installed correctly
can impair the function of the device and/or cause serious
or fatal injury to the user.

▪ Work on the device (e.g. set-up, inspection, connection

and initial commissioning) may only be carried out by
persons who are authorised and have 

successfully

completed qualifying technical or vocational train-
ing

, enabling them to perform the respective activity and

who have participated in advanced training courses re-
cognised by the relevant competent authority. These in-
clude, in particular, 

certified heating engineers, quali-

fied electricians and HVAC specialists

, who, because

of their 

professional training 

and their 

expert know-

ledge,

 have experience in the professional installation

and maintenance of heating systems, gas installations
and hot water tanks.

▪ Before starting any work on the device, switch off the ex-

ternal main switch and secure it against unintentional
switch-on.

▪ Do not leave any tools or other objects below the hood

of the device after finishing installation or maintenance
work.

Avoiding danger

The hot water storage tank is state of the art and is built to meet all
recognised technical requirements. However, improper use may res-
ult in serious physical injuries or death as well as property damage.
To avoid danger, only install and operate the device:

▪ as stipulated and in perfect condition,

▪ with an awareness of safety and the dangers involved.

This assumes knowledge and use of the contents of these operating
instructions, of the relevant accident prevention regulations as well
as the recognised safety-related and occupational health rules.

Before working on the heating system

▪ Only authorised and trained heating technicians may work on the

hot water storage tank (such as installation, connection and initial
commissioning).

▪ Switch off the external main switch before starting any work on the

hot water storage tank and secure it against unintentional switch-
on.

▪ Seals must not be damaged or removed.

▪ Make sure that the safety valves comply with the requirements of

EN 12828 when connecting on the heating side, and with the re-
quirements of EN 12897 when connecting on the domestic water
side.

▪ Only original replacement parts may be used.

1.2.2

Intended use

The device may only be used as a hot water storage tank. The
device must only be installed, connected and operated according to
the information in these operating instructions.

When connecting to an oil condensing boiler, only use the storage
tank connection kits provided for this purpose.

Only those electric immersion heaters supplied by the manufacturer
may be used.

Any other use outside the intended use is considered as improper.
The operator alone shall bear responsibility for any resulting dam-
age.

Содержание FLOSTO150

Страница 1: ...Installation and operating instructions Hot water storage tank English Installation and operating instructions FLOSTO150 03 2019...

Страница 2: ......

Страница 3: ...sion heater 9 3 2 2 Circulation brakes 9 3 2 3 Scalding protection 9 3 2 4 Circulation line connection 9 3 2 5 External current anode 9 3 2 6 Storage tank connection kit 9 4 Set up and installation 10...

Страница 4: ...t by children without supervision Make up the power supply in accord ance with IEC 60335 1 via a separ ator device which exhibits contact separation in all poles with a contact opening distance that p...

Страница 5: ...rform the respective activity and who have participated in advanced training courses re cognised by the relevant competent authority These in clude in particular certified heating engineers quali fied...

Страница 6: ...culated as calcium carbonate 3 mmol l Conductivity 1500 ideal 100 S cm Chloride 250 mg l Sulphate 250 mg l pH value heating water 6 5 8 5 Measures for desalination softening or hardness stabilisation...

Страница 7: ...s and operating manual to the operator and point out that these documents must be made available at all times and must be stored in the immediate vicinity of the device Document the handover by fillin...

Страница 8: ...tion Installation and operating instructions 8 Daikin FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN 3 Product description 3 1 Design and components Fig 3 1 View from front Fig 3 2 View fr...

Страница 9: ...n brakes To prevent heat loss from the connection pipes when the circulation pump is switched off and during periods when no domestic water is drawn off gravity circulation circulation brakes ZKB set...

Страница 10: ...device If there are any questions please contact our Technical Customer Service 4 1 2 Scope of delivery E F Fig 4 1 Scope of delivery Item Designation A Storage tank cladding side panel B Storage tan...

Страница 11: ...FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN Fig 4 3 Installing the hot water storage tank 4 1 4 Mounting removing the storage tank cladding Mounting the storage tank cladding Fig 4 4 In...

Страница 12: ...ccur when legionella protection is active or when the hot water target temperature is set to 60 C Fit scalding protection see Chap 3 2 3 For domestic water pipes observe the stipulations of EN 806 and...

Страница 13: ...loss Install the heat insulation in accordance with country specific guidelines The manufacturer recommends an insulation thickness of at least 20 mm 4 3 Filling Topping Up INFORMATION Any optional ac...

Страница 14: ...is an electric immersion heater set the required storage water temperature Switch on the mains supply switch on the heat generator Wait for the start phase Only if all points on the checklist can be a...

Страница 15: ...Open all water outlets 3 Connect the drain hose to the combined filling and draining valve of the storage tank 4 Open the combined filling and draining valve Fig 6 1 Draining the storage tank 6 2 1 D...

Страница 16: ...ment H 1 H 2 H m Heating circuits MAG Diaphragm expansion vessel MIX 3 way mixer with drive motor MK1 Mixer group with high efficiency pump MK2 Mixer group with high efficiency pump PWM regu lated P K...

Страница 17: ...ter storage tank 008 1632099_00 03 2019 EN PK SV MAG A2 F Flosto tV1 tR MIX H2 PMI tMI tAU M RoCon M1 H1 MK1 MK2 DHW VS tDHW DS SV CW F B n o C o R M A B AB 3UV DHW 3UVB1 FLS M B A AB tV2 Fig 7 2 Conn...

Страница 18: ...ating specialists authorised and recog nised by the energy supply company 8 1 Annual inspection If present Carry out a functional inspection of the electric immersion heater by checking the temperatur...

Страница 19: ...from the tank with the narrow side ahead Make sure that no parts can fall into the tank If necessary secure the lid with a cord Fig 8 4 Checking and cleaning the interior of the storage tank 6 Check a...

Страница 20: ...tinuous output QD according to DIN 4708 kW 49 Maximum draw off rate for the duration of 10 min on recharging at xx kW TkW 10 C TWW 40 C TSP 60 C l min 20 1 Hot water volume without reheating at a draw...

Страница 21: ...illibars m l h Flow rate in litres per hour m l min Flow rate in litres per minute Storage tank charging heat exchanger 1 9 3 Tightening torques Designation Thread size Tightening torque Hydraulic lin...

Страница 22: ...10 Notes Installation and operating instructions 22 Daikin FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN 10 Notes...

Страница 23: ...osal 15 Domestic water pipes 12 Draining the heating circuit 15 E Electric immersion heater 9 14 Electrical installation 6 External current anode 9 I Inspection 18 Installing the hot water storage tan...

Страница 24: ...008 1632099_00 03 2019 EN Copyright Daikin...