
4
Set-up and installation
Installation and operating instructions
13
Daikin FLOSTO150
Hot water storage tank
008.1632099_00 – 03/2019 – EN
3
If the pressure in the domestic water supply is greater, fit a pres-
sure reducer and limit the water pressure to < 6 bar.
4
Connect the cold water inlet to the hot water storage tank
(
, item 1).
INFORMATION
Above a hardness level of > 3 mmol/l, we recommend also
fitting a dirty water filter that can be back-flushed into the
cold water connection.
5
Connect the connections to the hot water distribution network
(
, item 2).
6
Make connections to the oil condensing boiler using the
DRTANKCOKITA storage tank connection set.
7
Carefully lag the hot water pipes to prevent heat loss. Install the
heat insulation in accordance with country-specific guidelines.
The manufacturer recommends an insulation thickness of at
least 20 mm.
4.3
Filling / Topping Up
INFORMATION
Any optional accessories must be fitted before filling.
INFORMATION
The heat exchanger must be filled before the hot water
storage tank.
4.3.1
Hot water storage tanks
DANGER: RISK OF ELECTROCUTION
Touching live parts can result in an electric shock and lead
to potentially fatal injuries and burns.
▪ If there is an electric immersion heater or an external
current anode installed in the hot water storage tank,
these components must be isolated from the power sup-
ply before starting work (e.g. fuse, main switch switched
off and secured against inadvertent switching on again).
1
Open all water outlets to vent the system.
2
Open the cold water pipe valve.
3
Check the system for leaks.
4
When the system is vented, close all water outlets.
Содержание FLOSTO150
Страница 2: ......
Страница 24: ...008 1632099_00 03 2019 EN Copyright Daikin...