Operation 

Adjusting the Airflow Rate/SMELL PROOF/CHILD LOCK Operation 

Adjusting the airflow rate 

You can adjust the airflow rate to increase your comfort. 

To change the airflow rate setting

Press (•FANJ.  • Each pressing of [•FANj changes the airflow rate setting in sequence.

1-1�---- l---1�.... I 

Indoor unit quiet 

Airflow rate 1-5 (Low to High) 

• In DRY operation, the airflow rate setting cannot be changed.

• When the airflow is set to"�", quiet operation starts and noise

from the indoor unit will become quieter.

• In the quiet operation mode, the airflow rate is set to a weak level.

SMELL PROOF operation 

The SMELL PROOF operation prevents unpleasant odour inside the indoor unit. This function is 

available in both DRY and COOL operation. 

To use SMELL PROOF operation

1. Before starting the operation, press (•FAN) to set to Auto.

2. Press (MooE) to select the DRY or COOL operation.

� . Air starts circulating about 1  minute after the operation is started.

3. Press�  However, if the POWER CHILL operation is started, air starts circulating

immediately. 

CHILD LOCK operation 

Setting the CHILD LOCK disables all the buttons except when 

ECONO 

and 

POWERFULL 

button

press together for about 5 seconds.

To set the CHILD LOCK : 

• Press 

t;ECONO) 

and � togetherfor about 5 seconds.

"wie" 

will be displayed on the remote LCD.• If a button is pressed while CHILD LOCK is on,• 

wie" 

blinks.

□ 

To  CANCEL the CHILD LOCK 

Presst;ECONO)and  �  together for about 5 seconds again.

" wie 

"Disappears from the LCD.

NOTE 

• Note on airflow rate setting

• At  smaller  airflow  rates,  the  cooling  effect  is also smaller.

• Note on SMELL PROOF operation

• SMELL  PROOF operation  can  prevent  some odours,  but  not all.

• Notes on the operating conditions

• The air conditioner always  consumes a  small  amount of  electricity even while it  is not  operating.

• If  you are not going  to  use the air  conditioner  for a long period,  turn  off the circuit breaker.

• Operation  outside  the humidity  or  temperature  range  described  in the table may  cause a

safety  device  to disable the system.

Mode 

Operating conditions 

If operation Is continued out of this range 

COOL 

Outdoor temperature: 20-(52-54

°

C)*  • A safety device may activate to stop the

Indoor temperature:  18-32

°

operation.

Max. temperature varying model to model. 

• Dew may form on the indoor unit and drip from it

DRY  Indoor humidity: 80% max. 

when COOL or DRY operation is selected.

Содержание F

Страница 1: ...MTKM60UV16U FTKT35UV16W FTKT50UV16V FTKT60UV16U FTKN35UV16W FTKN50UV16V A D F G MTKL35UV16W A D F G MTKL50UV16V A D F G MTKL50UV16U A D F GTKL60UV16U F GTKL71UV16T A F G MTKM50UV16VA F GTKC48UV16W F G...

Страница 2: ...ity and or longevity of the object concerned Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects Do not place appliances that produce naked flames i...

Страница 3: ...receiver Receives signals from the remote controller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Settings changed beep Operation stop long beep...

Страница 4: ...EEP DISPLAY button 15 DEW CLEAN button NOTE Notes on remote controller S NO 1 2 3 4 5 6 7 9 10 11 12 13 Never expose the remote controller to direct sunlight fJ 1 1 DAIICl fl D 2 REMOTE NO ARC484832 A...

Страница 5: ...er Do not get it wet The maximum transmission distance is about 7m To attach the accessory filters Set the accessory filters under the tabs of the filter frame on the indoor streamer unit When attachi...

Страница 6: ...ter and the decomposition power of the streamer discharge combine to reduce unpleasant odours and viruses cleaning the air in the room COANDA To start operation 1 Press C i i7 STREAMER When long press...

Страница 7: ...LOCK disables all the buttons except when ECONO and POWERFULL button press togetherfor about 5 seconds To set the CHILD LOCK Press t ECONO and togetherfor about 5 seconds wie will be displayed on the...

Страница 8: ...ction t ______ 1 Press swiNv and 7 1 and e are displayed on the LCD The flap and louvres move in turn To cancel 3 D airflow press either swiNGJ or ffiwiNG again The flap or louvres will stop moving To...

Страница 9: ...B causes the settings to be cancelled and disappears from the LCD ECONO operation functions in COOL and DRY operation POWER CHILL and ECONO operation cannot be used at the same time is displayed on th...

Страница 10: ...stop time default 2HR are displayed on the LCD i ol The TIMER lamp lights Display TEMP orange E 2 Press v while C is blinking Each pressing of the button changes tempera ture shift value by 1 C You ca...

Страница 11: ...on Set temperature does not display when the unit is in DRY operation or FAN operation Inverter output and set temperature may not display depending on the operation mode that is active The display tu...

Страница 12: ...F l hours 35 minutes Cooling operation To cancel DEW CLEAN operation Turn OFF the machine from Remote Controller Wi Fi Control NOTE Note on LED 7 Segment Brightness Control Ld indicates for the bright...

Страница 13: ...nt panel shaft on the other side in the same manner After disengaging both front panel shafts pull the front panel toward yourself and remove it 3 Clean the front panel Wipe it with a soft damp cloth...

Страница 14: ...ith a vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then let them dry in the shade Be sure to remove the accessory filter optional pa...

Страница 15: ...ting procedures Item Titanium apatite deodorizing air purifying filter 1 set Ag ion filter 1 set Anti Microbial filter 1 set Micro filter PM2 5 1 set Micro filter PM2 5 for streamer unit 1 set Micro f...

Страница 16: ...onditioner may stop operating after sudden large voltage fluctuations It automatically resumes operation in about 3 minutes Voltage range protection 130V 285V Voltage range protection 130V 265V for F...

Страница 17: ...been tripped or the fuse blown operate Is there a power failure OPERATION lamp is off Are batteries set in the remote controller Is the timer setting correct The room does not cool down Is the airflow...

Страница 18: ...air conditioner automatically resumes operation in about 3 minutes You should just wait for a while If there is a risk lightning could strike in the neighbourhood stop operation and turn off the circ...

Страница 19: ...N MOTOR FAULT ES OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING F8 1 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE ABNORMALITY OUTDOOR HO SENS...

Страница 20: ......

Страница 21: ...V16U F G MTKM60UV16U FTKT35UV16W FTKT50UV16V FTKT60UV16U FTKN35UV16W FTKN50UV16V A D F G MTKL35UV16W A D F G MTKL50UV16V A D F G MTKL50UV16U A D F GTKL60UV16U F GTKL71UV16T AJF GIMTKM50UV16VA F GTKC48...

Страница 22: ...rant gas leaks during installation ventilate the area immediately 0 Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for refrigerant gas le...

Страница 23: ...may cause interferencewith the picture or sound 9 the unit can be installed at the recommended height 1 8m 10 no laundry equipment is nearby The outdoor unit should be positioned in a place where 1 th...

Страница 24: ...lllq ral fir rufrlgerant pipe exaiedi 10min length Gas pipe Diameter mm Liquid pipe Diame1ar mm in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur de...

Страница 25: ...l the front grille and firmly engage the upper hooks 3 locations 2 Install 3 screws of the front grille 3 Install the air filter and then mount the front panel Opening the service lid The service lid...

Страница 26: ...298 X 821 X 235 298 X 885 X 229 298 X 906 X 235 Unit size available on name plate A B C 800 116 5 116 5 821 128 126 5 885 116 5 116 5 906 127 127 5 Table No 4 Applicable Unit Size Type H X W X D I 31...

Страница 27: ...on the edge ofthe indoor unit 9 Securethe indoor unit to the A mounting plate with the E indoorunit fixingscrews M4 x12L 10 Caulk the gap between the pipe andthe frontgrille with putty 11 After comple...

Страница 28: ...otincluded wi th the unit TableNo 6 WARNING Use a stabiliser if required by the voltage supply condition Do not use tapped wires extension cords or starburst connections as they may cause overheating...

Страница 29: ...g W f 3l Heat insulationpipe cover SI This illustration shows the case of the left rear piping Drain hose Sectional view wire J rwrap more than ha heat insu ation tape Heat Insulation pipe cover Insul...

Страница 30: ...ening torque tightening torque tightening torque 0 D 9 5mm 32 7 39 9N m 21 6 27 4N m 333 407 kgf cm 220 280 kgf cm Gas side 0 D 12 7mm 49 5 60 3N m 505 615 kgf cm 48 1 59 7N m 10 8 14 N m 0 D 15 9mm 6...

Страница 31: ...e all soapy water off 7 Disconnect charginghosefrom gasstop valve s service port thenfullyopenliquidandgasstop valves Do not attempt to tum valve rod beyond its stop 8 Tighten valve caps and service p...

Страница 32: ...noise No refrigerant gas leaks Incomplete cooling function Refrigerant gas and liquid pipes and indoor drain hose Water leakage extension are thermally insulated Draining line is properly installed W...

Страница 33: ...0020 Meaning of E waste under E Waste Management Rules 2022 E waste Rules Waste electrical and electronic equipment whole or in part of reject from their manufacturing and repair process which are int...

Отзывы: