5
Indoor Unit
Installing The Mounting Plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the
boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
Through-the-wall hole $65mm
t
Recommended mountfng plate
retention spell (7 spots m all)
Use a tape measure
as shown.
Position the end of
the tape measure at 1>
-
Applicable Unit Size*
Type [H] X [W] X [D]
CD
298
X
800
X
229
@
298
X
821
X
235
®
298
X
885
X
229
©
298
X
906
X
235
• Unit size available on name plate.
A
B
C
800 116.5 116.5
821 128 126.5
885 116.5 116.5
906 127 127.5
Table No.4
Applicable Unit Size*
,
Type
[H] X [W] X [D]
I
®
310
X
1100
X
239
Liquid pipe end
Gas pipe end Drah hose
position
• Unit size available on name plate.
Table No. 5
All dimensions are in mm.
Drilling A Wall Hole And Installing Wall Embedded Pipe
� WARNING---------------
For metal frame or metal board walls, be sure to use a wall embedded pipe and wall hole cover in the feed-through hole
to prevent possible heat, electrical shock, or fire.
1) Drill a feed-through hole with a 65mm
diameter through the wall at a
downward angle toward the outside.
2) Insert a wall embedded pipe into the hole.
3) Insert a wall hole oo.,er into wall pipe.
Wall hole cover
(field supply)
Inside ........ Outside