Fault diagnosis by remote controller 

T he remote controller can receive relevant error codes from the indoor unit. 

1. When 

(m) 

is held down for about 5 seconds, " 

(IJ 

blinks in the

temperature display section. 

2. Press 

(m) 

repeatedly until a long beep is produced.

• T he code indication changes as shown below, and notifies with a long beep.

CODE 

MEANING 

00 

NORMAL 

UA 

INDOOR-OUTDOOR UNIT COMBINATION FAULT 

SYSTEM 

uo 

REFRIGERANT SHORTAGE 

U2 

DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE 

U4 

FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT) 

A1 

INDOOR PCB DEFECTIVENESS 

A5 

FREEZE-UP PROTECTOR 

INDOOR 

A6 

FAN MOTOR FAULT 

UNIT 

C4 

FAULTY HEAT EXCHANGER TEMPERATURE SENSOR 

C9 

FAULTY SUCTION AIR TEMPERATURE SENSOR 

E1 

CIRCUIT BOARD FAULT 

ES 

OL STARTED 

E6 

FAULTY COMPRESSOR START UP 

E7 

DC FAN MOTOR FAULT 

ES 

OVERCURRENT INPUT 

F3 

HIGH TEMPERATURE DISCHARGE PIPE CONTROL 

F6 

HIGH PRESSURE CONTROL (IN COOLING) 

F8 

OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE ABNORMALITY

OUTDOOR 

HO 

SENSOR FAULT 

UNIT 

H6 

OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR 

H8 

DC CURRENT SENSOR FAULT 

H9 

FAULTY SUCTION AIR TEMPERATURE SENSOR 

J3 

FAULTY DISCHARGE PIPE TEMPERATURE SENSOR 

J6 

FAULTY HEAT EXCHANGER TEMPERATURE SENSOR 

L3 

ELECTRICAL  PARTS HEAT FAULT 

L4 

HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK 

LS 

OUTPUT OVERCURRENT 

P4 

FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR 

NOTE 

• A short beep indicates non-corresponding codes.
• To cancel the code display, hold down (CANCEL) for about 5 seconds.

The code display also cancels itself if the button is not pressed for 1  minute.

DAIKIN INDUSTRIES, LTD. 

Head office: 

Osaka Umeda Twin Towers Sooth 

1-13-1, Umeda, Kita-ku, Osaka 530-0001, Japan

Tokyo office: 

Yaesu Central Tower, Td<yoMidtown Yaesu, 

2-2-1, Yaesu, Chuo-ku, Td<yo, 104-0028, Japan

http://www.daikin.com

El 

Содержание F

Страница 1: ...MTKM60UV16U FTKT35UV16W FTKT50UV16V FTKT60UV16U FTKN35UV16W FTKN50UV16V A D F G MTKL35UV16W A D F G MTKL50UV16V A D F G MTKL50UV16U A D F GTKL60UV16U F GTKL71UV16T A F G MTKM50UV16VA F GTKC48UV16W F G...

Страница 2: ...ity and or longevity of the object concerned Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects Do not place appliances that produce naked flames i...

Страница 3: ...receiver Receives signals from the remote controller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Settings changed beep Operation stop long beep...

Страница 4: ...EEP DISPLAY button 15 DEW CLEAN button NOTE Notes on remote controller S NO 1 2 3 4 5 6 7 9 10 11 12 13 Never expose the remote controller to direct sunlight fJ 1 1 DAIICl fl D 2 REMOTE NO ARC484832 A...

Страница 5: ...er Do not get it wet The maximum transmission distance is about 7m To attach the accessory filters Set the accessory filters under the tabs of the filter frame on the indoor streamer unit When attachi...

Страница 6: ...ter and the decomposition power of the streamer discharge combine to reduce unpleasant odours and viruses cleaning the air in the room COANDA To start operation 1 Press C i i7 STREAMER When long press...

Страница 7: ...LOCK disables all the buttons except when ECONO and POWERFULL button press togetherfor about 5 seconds To set the CHILD LOCK Press t ECONO and togetherfor about 5 seconds wie will be displayed on the...

Страница 8: ...ction t ______ 1 Press swiNv and 7 1 and e are displayed on the LCD The flap and louvres move in turn To cancel 3 D airflow press either swiNGJ or ffiwiNG again The flap or louvres will stop moving To...

Страница 9: ...B causes the settings to be cancelled and disappears from the LCD ECONO operation functions in COOL and DRY operation POWER CHILL and ECONO operation cannot be used at the same time is displayed on th...

Страница 10: ...stop time default 2HR are displayed on the LCD i ol The TIMER lamp lights Display TEMP orange E 2 Press v while C is blinking Each pressing of the button changes tempera ture shift value by 1 C You ca...

Страница 11: ...on Set temperature does not display when the unit is in DRY operation or FAN operation Inverter output and set temperature may not display depending on the operation mode that is active The display tu...

Страница 12: ...F l hours 35 minutes Cooling operation To cancel DEW CLEAN operation Turn OFF the machine from Remote Controller Wi Fi Control NOTE Note on LED 7 Segment Brightness Control Ld indicates for the bright...

Страница 13: ...nt panel shaft on the other side in the same manner After disengaging both front panel shafts pull the front panel toward yourself and remove it 3 Clean the front panel Wipe it with a soft damp cloth...

Страница 14: ...ith a vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then let them dry in the shade Be sure to remove the accessory filter optional pa...

Страница 15: ...ting procedures Item Titanium apatite deodorizing air purifying filter 1 set Ag ion filter 1 set Anti Microbial filter 1 set Micro filter PM2 5 1 set Micro filter PM2 5 for streamer unit 1 set Micro f...

Страница 16: ...onditioner may stop operating after sudden large voltage fluctuations It automatically resumes operation in about 3 minutes Voltage range protection 130V 285V Voltage range protection 130V 265V for F...

Страница 17: ...been tripped or the fuse blown operate Is there a power failure OPERATION lamp is off Are batteries set in the remote controller Is the timer setting correct The room does not cool down Is the airflow...

Страница 18: ...air conditioner automatically resumes operation in about 3 minutes You should just wait for a while If there is a risk lightning could strike in the neighbourhood stop operation and turn off the circ...

Страница 19: ...N MOTOR FAULT ES OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING F8 1 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE ABNORMALITY OUTDOOR HO SENS...

Страница 20: ......

Страница 21: ...V16U F G MTKM60UV16U FTKT35UV16W FTKT50UV16V FTKT60UV16U FTKN35UV16W FTKN50UV16V A D F G MTKL35UV16W A D F G MTKL50UV16V A D F G MTKL50UV16U A D F GTKL60UV16U F GTKL71UV16T AJF GIMTKM50UV16VA F GTKC48...

Страница 22: ...rant gas leaks during installation ventilate the area immediately 0 Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for refrigerant gas le...

Страница 23: ...may cause interferencewith the picture or sound 9 the unit can be installed at the recommended height 1 8m 10 no laundry equipment is nearby The outdoor unit should be positioned in a place where 1 th...

Страница 24: ...lllq ral fir rufrlgerant pipe exaiedi 10min length Gas pipe Diameter mm Liquid pipe Diame1ar mm in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur de...

Страница 25: ...l the front grille and firmly engage the upper hooks 3 locations 2 Install 3 screws of the front grille 3 Install the air filter and then mount the front panel Opening the service lid The service lid...

Страница 26: ...298 X 821 X 235 298 X 885 X 229 298 X 906 X 235 Unit size available on name plate A B C 800 116 5 116 5 821 128 126 5 885 116 5 116 5 906 127 127 5 Table No 4 Applicable Unit Size Type H X W X D I 31...

Страница 27: ...on the edge ofthe indoor unit 9 Securethe indoor unit to the A mounting plate with the E indoorunit fixingscrews M4 x12L 10 Caulk the gap between the pipe andthe frontgrille with putty 11 After comple...

Страница 28: ...otincluded wi th the unit TableNo 6 WARNING Use a stabiliser if required by the voltage supply condition Do not use tapped wires extension cords or starburst connections as they may cause overheating...

Страница 29: ...g W f 3l Heat insulationpipe cover SI This illustration shows the case of the left rear piping Drain hose Sectional view wire J rwrap more than ha heat insu ation tape Heat Insulation pipe cover Insul...

Страница 30: ...ening torque tightening torque tightening torque 0 D 9 5mm 32 7 39 9N m 21 6 27 4N m 333 407 kgf cm 220 280 kgf cm Gas side 0 D 12 7mm 49 5 60 3N m 505 615 kgf cm 48 1 59 7N m 10 8 14 N m 0 D 15 9mm 6...

Страница 31: ...e all soapy water off 7 Disconnect charginghosefrom gasstop valve s service port thenfullyopenliquidandgasstop valves Do not attempt to tum valve rod beyond its stop 8 Tighten valve caps and service p...

Страница 32: ...noise No refrigerant gas leaks Incomplete cooling function Refrigerant gas and liquid pipes and indoor drain hose Water leakage extension are thermally insulated Draining line is properly installed W...

Страница 33: ...0020 Meaning of E waste under E Waste Management Rules 2022 E waste Rules Waste electrical and electronic equipment whole or in part of reject from their manufacturing and repair process which are int...

Отзывы: