6/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.1.A
[0-07]
R/W
10~25°C, step: 1°C
20°C
└─
Tank
9.1.B.1
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
9.1.B.2
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
9.1.B.3
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.4
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.5
[6-08]
R/W
2~20°C, step: 1°C
10°C
└─
Domestic hot water
9.2.1
[E-05]
[E-06]
[E-07]
R/W
No DHW (*3)
EKHW, small volume (*3)
Integrated (*4)
EKHW, big volume (*3)
EKHWP (*3)
3rd party, small coil (*3)
3rd party, big coil (*3)
9.2.2
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.2.4
[D-07]
R/W
0: No
1: Yes
└─
Back up heater
9.3.1
[E-03]
R/O
3: 6V (*1)
4: 9W (*2)
9.3.2
[5-0D]
R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V, 3~ (*2)
9.3.3
[4-0A]
R/W
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.3.4
[6-03]
R/W
0~10kW, step: 0,2kW
2kW (*1)
3kW (*2)
9.3.5
[6-04]
R/W
0~10kW, step: 0,2kW
4kW (*1)
6kW (*2)
9.3.6
[5-00]
R/W
0: No
1: Yes
9.3.7
[5-01]
R/W
-15~35°C, step: 1°C
0°C
9.3.8
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
└─
Booster heater
9.4.1
[6-02]
R/W
0~10kW, step: 0,2kW
3kW (*3)
0kW (*4)
9.4.3
[8-03]
R/W
20~95 min, step: 5 min
50 min
9.4.4
[4-03]
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
└─
Emergency
9.5.1
[4-06]
R/W
0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.5.2
[7-06]
R/W
0: Disabled
1: Enabled
└─
Balancing
9.6.1
[5-02]
R/W
0: Disabled
1: Enabled
9.6.2
[5-03]
R/W
-15~35°C, step: 1°C
0°C
9.6.3
[5-04]
R/W
0~20°C, step: 1°C
10°C
9.6.4
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour [E-07]
≠
1
9.6.5
[8-00]
R/W
0~20 min, step 1 min
1 min
9.6.6
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.6.7
[8-04]
R/W
0~95 min, step: 5 min
95 min
Installer settings
9.7
[4-04]
R/W
0: Intermittent
1: Continuous
2: Off
└─
Benefit kWh power supply
9.8.2
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.8.3
[D-05]
R/W
0: Forced off
1: As normal
9.8.4
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
Anti-recycle timer
Minimum running timer
Maximum running timer
Additional timer
Water pipe freeze prevention
Allow heater
Allow pump
Benefit kWh power supply
Operation
Emergency
Compressor forced OFF
Space heating priority
Priority temperature
Offset BSH setpoint
Additional capacity step 2
Equilibrium: Deactivate backup heater (or external backup heat source in case of a b
Equilibrium temperature
Operation
Capacity
BSH eco timer
DHW pump
Solar
BUH type
Voltage
Configuration
Capacity step 1
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
Reheat hysteresis
Domestic hot water
Low ambient temp. for LWT add zone cooling WD curve.
4P644734-1 - 2021.02
(#) Only applicable in Swedish language.
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*