background image

2

 | 

Quick guide

User reference guide

10

ETVH/9W(G) + ETBH/9W

Daikin Altherma 3 H HT F+W

4P586456-1B – 2020.10

"4.4 Turning operation ON or OFF"

 [

4

 26]

"4.6 Space heating/cooling control"

 [

4

 29]

"4.8 Preset values and schedules"

 [

4

 37]

"4.9 Weather-dependent curve"

 [

4

 47]

Содержание ETBH16DF9W

Страница 1: ...ence guide Daikin Altherma 3 H HT F W ETVH16S18DA6V G ETVH16S23DA6V G ETVH16S18DA9W G ETVH16S23DA9W G ETVX16S18DA6V G ETVX16S23DA6V G ETVX16S18DA9W G ETVX16S23DA9W G ETBH16DF6V ETBH16DF9W ETBX16DF6V E...

Страница 2: ...out information 28 Possible read out information 28 4 6 Space heating cooling control 29 4 6 1 About space heating cooling control 29 4 6 2 Setting the space operation mode 29 4 6 3 Determining which...

Страница 3: ...help text in case of a malfunction 57 7 2 To check the malfunction history 57 7 3 Symptom You are feeling too cold hot in your living room 58 7 4 Symptom The water at the tap is too cold 58 7 5 Sympt...

Страница 4: ...read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Booster heater capacity 9 4 1 if applicable Backup heater Voltage 9 3 2 Configurat...

Страница 5: ...Altherma 3 H HT F W 4P586456 1B 2020 10 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 1 2 Settings menu Sett...

Страница 6: ...nced user You can read out and edit more information To change the user permission level 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level Browse thro...

Страница 7: ...ooling operation C 2 Operation Space heating cooling room frost protection if enabled will remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Op...

Страница 8: ...tpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water temperature 35 C 2...

Страница 9: ...X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1 is equally higher as the preferred temperature at X2 Y1 Y2 Y3 Y4 X1 X2 a b c d X1 X2 Outdoor ambient temp...

Страница 10: ...e 10 ETVH X16S18 23DA6V 9W G ETBH X16DF6V 9W Daikin Altherma 3 H HT F W 4P586456 1B 2020 10 4 4 Turning operation ON or OFF 426 4 6 Space heating cooling control 429 4 8 Preset values and schedules 43...

Страница 11: ...ion to On or Off To change the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank T...

Страница 12: ...ies or lack of experience and knowledge can only use this appliance if they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Chil...

Страница 13: ...chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facil...

Страница 14: ...ructions Format Paper in the box of the indoor unit Installer reference guide Preparation of the installation good practices reference data Format Digital files on http www daikineurope com support an...

Страница 15: ...to Space heating cooling 4 Space heating cooling 2 Press the left dial to enter the submenu 3 Turn the left dial and go to Operation range Operation range 4 3 4 Press the left dial to enter the subme...

Страница 16: ...asks read the service manual For more information see the installer and user reference guide The unit contains rotating parts Be careful when servicing or inspecting the unit Symbols used in the docum...

Страница 17: ...ne Example Bedroom C Technical room Example Garage a Outdoor unit heat pump b Indoor unit heat pump c Domestic hot water DHW tank d User interface of the indoor unit e Dedicated Human Comfort Interfac...

Страница 18: ...Dials and buttons Status indicator The LEDs of the status indicator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Con...

Страница 19: ...dial Choose a menu item Press the left dial Confirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help...

Страница 20: ...rs Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cooling Tank 1 4 Antifrost Activation Room setpoint 1 5 Setpoint range Heating minimum...

Страница 21: ...c3 Screen with weather dependent curve c4 Screen with schedule 4 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint...

Страница 22: ...ode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currently being used for space heating e3 Smart ene...

Страница 23: ...type Underfloor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room therm...

Страница 24: ...ted Human Comfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the lea...

Страница 25: ...ing the Daikin Residential Controller app 4 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen...

Страница 26: ...date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and pr...

Страница 27: ...f Tank heating operation OFF 4 4 2 To turn ON or OFF Room temperature control 1 Go to C 1 Operation Room Operation Room Space heating cooling On On C 1 2 Set operation to On or Off Space heating cool...

Страница 28: ...ling C 3 2 Set operation to On or Off 4 5 Reading out information To read out information 1 Go to 8 Information Possible read out information In menu You can read out 8 1 Energy data Produced energy c...

Страница 29: ...it can both heat up and cool down a space You have to tell the system which operation mode to use To determine if a heating cooling heat pump model is installed 1 Go to 4 Space heating cooling 2 Check...

Страница 30: ...atic 1 Go to 4 2 Space heating cooling Operation mode schedule 2 Select a month 3 For each month select an option Reversible Not restricted Heating only Restricted Cooling only Restricted 4 Confirm th...

Страница 31: ...icon Leaving water temperature control Leaving water temperature control 4 6 4 To change the desired room temperature During room temperature control you can use the room temperature setpoint screen...

Страница 32: ...esired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water temperature 35 C 2 a b Main zone 45 C 3 a b Additional zone a...

Страница 33: ...ORMATION In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping following actions are recommended When the Reheat only or Schedule reheat...

Страница 34: ...t Time INFORMATION Risk of space heating capacity shortage for domestic hot water tank without internal booster heater In case of frequent domestic hot water operation frequent and long space heating...

Страница 35: ...water again and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats 4 7 4 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in...

Страница 36: ...heated by the backup heater or booster heater Use this mode on days when there is more hot water usage than usual To check if powerful operation is active If is displayed on the home screen powerful o...

Страница 37: ...The software uses this preset value if the DHW tank mode is Schedule reheat Electricity prices under 7 5 User settings Electricity price Restriction Only applicable if Bivalent is enabled by the insta...

Страница 38: ...timer 1 Go to 7 5 4 User settings Electricity price Schedule 2 Program the selection using the scheduling screen You can set the High Medium and Low electricity prices according to your electricity su...

Страница 39: ...ity price Electricity price Actual electricity price Incentive kWh Electricity price 12 49 5 Electricity price 17 49 Price Value in breadcrumb Gas 4 08 kWh 7 6 8 6 Electricity 12 49 kWh 7 5 1 17 4 8 3...

Страница 40: ...ther schedule See To select which schedule you currently want to use 440 Program your own schedule See 4 8 4 Schedule screen Example 443 Predefined schedules Number of available predefined schedules i...

Страница 41: ...hin range Otherwise Temperatures within range 3 2 Additional zone Heating schedule Schedule for when the system is allowed to heat up the additional zone in heating mode Predefined schedules 1 Activat...

Страница 42: ...also takes the user defined preset value 5 4 Reheat setpoint into account 7 4 2 User settings Quiet Schedule Schedule for when the unit has to use which quiet mode level Predefined schedules 1 Activat...

Страница 43: ...room thermostat control is active If leaving water temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week sch...

Страница 44: ...ined 1 2 Select Edit Delete Edit Copy 3 Use the left dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker...

Страница 45: ...efined 1 2 Select Copy Delete Edit Copy Result Next to the copied day C is displayed 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat...

Страница 46: ...of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displa...

Страница 47: ...r temperature and water temperature at tap points Advantage Weather dependent operation reduces energy consumption Weather dependent curve To be able to compensate for differences in temperature the u...

Страница 48: ...through the temperatures Change the temperature Go to the next temperature Confirm changes and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and of...

Страница 49: ...ew preferred temperature at X1 is unequally higher than the preferred temperature at X2 When offset is changed the new preferred temperature at X1 is equally higher as the preferred temperature at X2...

Страница 50: ...ode WD heating fixed cooling OR Weather dependent Main zone Cooling 2 4 Main zone Setpoint mode Weather dependent Additional zone Heating 3 4 Additional zone Setpoint mode WD heating fixed cooling OR...

Страница 51: ...mum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dependent curve of a zo...

Страница 52: ...e INFORMATION If the outdoor temperature is below zero we recommend to NOT use the most quiet level To check if quiet mode is active If is displayed on the home screen quiet mode is active To program...

Страница 53: ...e the holiday 1 Activate the holiday mode Go to 7 3 1 User settings Holiday Activation Activation Till 7 3 1 From Select On 2 Set the first day of your holiday Go to 7 3 2 From Select a date Confirm t...

Страница 54: ...on are needed on the user interface of the indoor unit D Wireless gateway Malfunctioning Operation User profile Room D Wireless gateway D 1 Mode D 2 WPS D 3 Reboot D 4 Device info D 1 Mode Turn mode O...

Страница 55: ...or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in...

Страница 56: ...equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mi...

Страница 57: ...n In case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the...

Страница 58: ...h the heat emitter type See 4 6 5 To change the desired leaving water temperature 432 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 4 9 Weather dependent curve...

Страница 59: ...ting is reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH normal DHW off space heating operates as norm...

Страница 60: ...ore you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want...

Страница 61: ...6DF6V 9W Daikin Altherma 3 H HT F W 4P586456 1B 2020 10 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk numbe...

Страница 62: ...HT F W 4P586456 1B 2020 10 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislat...

Страница 63: ...ct or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application...

Страница 64: ...4P586456 1B 2020 10 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: