Types of weather-dependent curve
There are 2 types of weather-dependent curves:
▪
2-points curve
▪
Slope-offset curve
Which type of curve you use to make adjustments, depends on your personal
preference. See
"11.5.4 Using weather-dependent curves"
171].
Availability
The weather-dependent curve is available for:
▪
Main zone - Heating
▪
Main zone - Cooling
▪
Additional zone - Heating
▪
Additional zone - Cooling
▪
Tank (only available to installers)
INFORMATION
To operate weather-dependent, correctly configure the setpoint of the main zone,
additional zone or tank. See
"11.5.4 Using weather-dependent curves"
11.5.2 2-points curve
Define the weather-dependent curve with these two setpoints:
▪
Setpoint (X1, Y2)
▪
Setpoint (X2, Y1)
Example
Y1
Y2
X1