background image

EKHVH/X00 EKHVH/9WN

Daikin Altherma indoor unit

4PW64330-1 – 07.2010

Operation manual

8

4.

Domestic water heating (refer to 

"Programming space heating or

domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. The switch set to
on means enabeling the programmed storage and reheat
operation. Four actions per weekday can be programmed,
totalling 28 actions.

What can the schedule timer NOT do?

The schedule timer can not change the operation mode from space
cooling to space heating or vice versa.

How to interpret the programmed actions

To be able to understand the behaviour of your installation when the
schedule timer is enabled, it is important to keep in mind that the
"last" programmed command overruled the "preceding" programmed
command and will remain active until the "next" programmed
command occurs.

Example: imagine the actual time is 17:30 and actions are
programmed at 13:00, 16:00 and 19:00. The "last" programmed
command (16:00) overruled the "previous" programmed command
(13:00) and will remain active until the "next" programmed command
(19:00) occurs.

So in order to know the actual setting, one should consult the last
programmed command. It is clear that the "last" programmed
command may date from the day before. Refer to 

"Consulting

programmed actions" on page 10

.

4.7.

Programming and consulting the schedule timer

Getting started

Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:

Familiarise yourself with the icons and the buttons. You will need
them when programming. Refer to 

"Name and function of

buttons and icons" on page 4

.

Fill out the form at the very end of this manual. This form can
help you define the required actions for each day. Keep in mind
that:
-

In the space heating and domestic water heating program, 
four actions can be programmed per weekday. The same 
actions are repeated on a weekly basis.

-

In the space cooling and quiet mode program, four actions 
can be programmed per mode. The same actions are 
repeated on a daily basis.

Take your time to enter all data accurately.

Try to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.

If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.

You can always alter, add or remove the programmed actions
later.

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

In case no domestic water heating actions are
programmed, enabling or disabling the schedule timer
will only have influence on the space heating, cooling
and quite mode. In this way it is possible to separate
on one hand the space heating, cooling and quite
mode scheduled action as part of the schedule timer
and on the other hand the storage and reheat
operation of the domestic water heating.

In this way, it is easy to disable the space heating and
cooling by disabling the schedule timer with keeping
the storage and reheat domestic water heating
enabled (refer to 

"Scheduled domestic hot water

storage" on page 

15

 and 

"Scheduled/continuous

domestic hot water reheat" on page 15

).

During schedule timer operation, someone may have
altered the actual settings manually (in other words, the
"last" command was overruled manually). The icon 

p

,

indicating the schedule timer operation, may still be
displayed, giving the impression that the "last" command
settings are still active. The "next" programmed command
will overrule the altered settings and return to the original
program.

Содержание EKHVH008BB6V3

Страница 1: ...OPERATION MANUAL EKHVH008BB6V3 EKHVX008BB6V3 EKHVH008BB6WN EKHVX008BB6WN EKHVH008BB9WN EKHVX008BB9WN Daikin Altherma indoor unit...

Страница 2: ...1 2 Meaning of used terms Installation manual Instruction manual speci ed for a certain product or application explaining how to install con gure and maintain it Operation manual Instruction manual s...

Страница 3: ...ual of the indoor unit and to the installation manual of the digital I O PCB for more information Refer to the wiring diagram or connection diagram for connecting this PCB to the unit Remote thermosta...

Страница 4: ...ough the tap it will probably make a sound as of air escaping 4 2 Operating the digital controller Operating the EKHV unit comes down to operating the digital controller Features and functions The dig...

Страница 5: ...timer 9 OFF ICON x This icon indicates that the OFF action is selected when programming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the instal...

Страница 6: ...nstalled 34 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set in permission level 2 or 3 refer to Field settings on page 12 the quiet mode button will not be oper...

Страница 7: ...tons to set the desired water temperature Temperature range for heating 25 C to 55 C The temperature for heating can be set as low as 15 C see Field settings on page 12 However the temperature for hea...

Страница 8: ...programmed command of the schedule timer occurs The schedule timer is enabled p icon displayed or disabled p icon not displayed by pressing the pr button To set up the SCHEDULE TIMER refer to chapter...

Страница 9: ...grammed per weekday The same actions are repeated on a weekly basis In the space cooling and quiet mode program four actions can be programmed per mode The same actions are repeated on a daily basis T...

Страница 10: ...e programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the...

Страница 11: ...other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 10 Press the button for 5 seconds to store th...

Страница 12: ...essing the pr button 3 Press the button to con rm the selected mode The actual day is blinking 4 Select the day you would like to copy to the next day by means of the pi and pj buttons The selected da...

Страница 13: ...FIELD SET MODE The icon 3 will be displayed The current selected eld setting code is indicated 2 with the set value displayed to the right 1 2 Press the bgi button to select the appropriate eld settin...

Страница 14: ...low ambient temperature Lo_A Note that the Lo_Ti value should be higher than Hi_Ti as for colder outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_T...

Страница 15: ...temperature TU User set point temperature as set on the user interface TH High set point temperature 2 03 t Time WARNING Be aware that the domestic hot water temperature at the hot water tap will be e...

Страница 16: ...mestic hot water is enabled by the w button A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domestic hot water user interface set point Tdhw e g 55 C is reached B Sch...

Страница 17: ...hift value of the weather dependent set point around outdoor temperature of 0 C E Unit information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23...

Страница 18: ...without built in booster heater 4 05 5 60 40 60 5 min 3 Auto restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating...

Страница 19: ...4 Installation related setting 05 Installation related setting D Bene t kWh rate power supply local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Ins...

Страница 20: ...th unsorted household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a quali ed installer in accord...

Страница 21: ......

Страница 22: ...4PW64330 1 07 2010 Copyright 2010 Daikin...

Отзывы: