DOMESTIC WATER HEATING BUTTON 

v

This button enables or disables storage and reheating of the
domestic water. 

This button is not used when the domestic hot water tank is not
installed.

27.

WEATHER DEPENDENT SET POINT BUTTON 

ba

This button enables or disables the weather dependent set point
function which is available in space heating operation only.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 12

), the weather dependent set point button

will not be operable.

28.

INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to 

"Field settings" on page 12

.

29.

PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

30.

SCHEDULE TIMER BUTTON 

r

/

p

The main function of this multi-purpose button is to
enable/disable the schedule timer.

The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.

If the controller is set in permission level 3 (refer to 

"Field

settings" on page 12

), the schedule timer button will not be

operable.

31.

TIME ADJUST BUTTON 

pi

 and 

pj

These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
indoor unit, outdoor ambient temperature and domestic hot
water temperature) and in schedule timer programming mode.

32.

TEMPERATURE ADJUST BUTTONS 

bi

 and 

bj

These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.

33.

DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS

wbi

 and 

wbj

These buttons are used to adjust the current set storage point of
the domestic hot water temperature.

The buttons are not used when the domestic hot water tank is
not installed.

34.

QUIET MODE BUTTON 

s

This button enables or disables quiet mode.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 12

), the quiet mode button will not be

operable.

4.4.

Setting up the controller

After initial installation, the user can set the clock and day of the
week.

The controller is equipped with a schedule timer that enables the user
to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.

Setting the clock

1

Hold down the 

pr

 button for 5 seconds.

The clock read-out and the day of week indicator start flashing.

2

Use the 

pi

 and 

pj

 buttons to adjust the clock.

Each time the 

pi

 or 

pj

 button is pressed, the time will

increase/decrease by 1 minute. Keeping the 

pi

 or 

pj

button pressed will increase/decrease the time by 10 minutes.

3

Use the 

bi

 or 

bj

 button to adjust the day of the week.

Each time the 

bi

 or 

bj

 button is pressed the next or

previous day is displayed.

4

Press the 

<

 button to confirm the current set time and day of the

week.

To leave this procedure without saving, press the 

pr

 button.

If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.

Setting the schedule timer

To set the schedule timer, refer to chapter 

"Programming and

consulting the schedule timer" on page 8

.

4.5.

Description of the operation modes

Space heating operation (

h

)

In this mode, heating will be activated as required by the water
temperature set point. The set point can be set manually (refer to

"Manual operation" on page 6

) or weather dependent (refer to

"Selecting weather dependent set point operation (only in heating
mode)" on page 7

).

Startup (

d

)

At the start of a heating operation, the pump is not started until a
certain refrigerant heat exchanger temperature is reached. This
guarantees correct startup of the heat pump. During startup, icon

d

 is displayed.

Defrost (

d

)

In space heating operation or heat pump domestic water heating
operation, freezing of the outdoor heat exchanger may occur due to
low outdoor temperature. If this risk occurs, the system goes into
defrost operation. It reverses the cycle and takes heat from the indoor
system to prevent freezing of the outdoor system. After a maximum
of 8 minutes of defrost operation, the system returns to the previous
mode.

The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and vice
versa.

Содержание EKHVH008BB6V3

Страница 1: ...OPERATION MANUAL EKHVH008BB6V3 EKHVX008BB6V3 EKHVH008BB6WN EKHVX008BB6WN EKHVH008BB9WN EKHVX008BB9WN Daikin Altherma indoor unit...

Страница 2: ...1 2 Meaning of used terms Installation manual Instruction manual speci ed for a certain product or application explaining how to install con gure and maintain it Operation manual Instruction manual s...

Страница 3: ...ual of the indoor unit and to the installation manual of the digital I O PCB for more information Refer to the wiring diagram or connection diagram for connecting this PCB to the unit Remote thermosta...

Страница 4: ...ough the tap it will probably make a sound as of air escaping 4 2 Operating the digital controller Operating the EKHV unit comes down to operating the digital controller Features and functions The dig...

Страница 5: ...timer 9 OFF ICON x This icon indicates that the OFF action is selected when programming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the instal...

Страница 6: ...nstalled 34 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set in permission level 2 or 3 refer to Field settings on page 12 the quiet mode button will not be oper...

Страница 7: ...tons to set the desired water temperature Temperature range for heating 25 C to 55 C The temperature for heating can be set as low as 15 C see Field settings on page 12 However the temperature for hea...

Страница 8: ...programmed command of the schedule timer occurs The schedule timer is enabled p icon displayed or disabled p icon not displayed by pressing the pr button To set up the SCHEDULE TIMER refer to chapter...

Страница 9: ...grammed per weekday The same actions are repeated on a weekly basis In the space cooling and quiet mode program four actions can be programmed per mode The same actions are repeated on a daily basis T...

Страница 10: ...e programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the...

Страница 11: ...other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 10 Press the button for 5 seconds to store th...

Страница 12: ...essing the pr button 3 Press the button to con rm the selected mode The actual day is blinking 4 Select the day you would like to copy to the next day by means of the pi and pj buttons The selected da...

Страница 13: ...FIELD SET MODE The icon 3 will be displayed The current selected eld setting code is indicated 2 with the set value displayed to the right 1 2 Press the bgi button to select the appropriate eld settin...

Страница 14: ...low ambient temperature Lo_A Note that the Lo_Ti value should be higher than Hi_Ti as for colder outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_T...

Страница 15: ...temperature TU User set point temperature as set on the user interface TH High set point temperature 2 03 t Time WARNING Be aware that the domestic hot water temperature at the hot water tap will be e...

Страница 16: ...mestic hot water is enabled by the w button A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domestic hot water user interface set point Tdhw e g 55 C is reached B Sch...

Страница 17: ...hift value of the weather dependent set point around outdoor temperature of 0 C E Unit information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23...

Страница 18: ...without built in booster heater 4 05 5 60 40 60 5 min 3 Auto restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating...

Страница 19: ...4 Installation related setting 05 Installation related setting D Bene t kWh rate power supply local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Ins...

Страница 20: ...th unsorted household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a quali ed installer in accord...

Страница 21: ......

Страница 22: ...4PW64330 1 07 2010 Copyright 2010 Daikin...

Отзывы: