6
EK260AA + EKUHWHTA
Domestic hot water tank with UK kit for air to water heat pump system
4PW53247-1B
6
Mount the tank module on top of the indoor unit using the lifting
holes.
7
Connect the flexible hoses as indicated in
.
■
The 2 flexible hoses with quick coupling connections on both
sides must be connected to the coil connection as indicated
in
■
The 2 flexible hoses with quick coupling connection on one
side and threaded connection coupling on the other side
must be connected to the hot water outlet and cold water
inlet (they have to be routed out from the rear plate (see
). Depending on the installation location (left or right
side installation), punch the required right or left knockout
holes out of the rear plate. Apply the grommet to the edges of
the knocked out holes to protect the flexible piping.
If the recirculation connection is used, connect a tube with
threaded connection to this hole and guide it through a hole
in the rear plate too.
8
Fix the side bottom decoration panels of the domestic hot water
tank to the indoor unit.
9
Connect the accessories supplied with the EKUHWHTA kit as
explained in
"Installation of the EKUHWHTA kit on the domestic
10
Connect the thermistor wire to the indoor unit switch box. Make
sure power supply is switched off. Refer to the wiring diagram
delivered with the indoor unit.
The distance between the thermistor cable and power supply
cable must always be at least 5 cm to prevent electromagnetic
interference on the thermistor cable.
1 Plug the thermistor cable connector in the socket X11A on
the PCB.
2 Fix the cables to the cable tie mountings with cable ties to
ensure strain relief.
3 When routing out cables, make sure that these do not
obstruct mounting of the indoor unit cover.
Because of the weight of the domestic hot water tank,
it is advised to handle and lift it with two persons.
1
Hot water out connection (G 3/4" Female)
2
Cold water in connection (G 3/4" Female)
3
Hot water out connection at the bottom of the tank (quick
coupling)
4
Cold water in connection at the bottom of the tank (quick
coupling)
5
Recirculation connection (G 1/2" Male)
6
Flow inlet connection from the main EKHBRD indoor unit
(quick coupling)
7
Return outlet connection to the main EKHBRD indoor unit
(quick coupling)
8
3-way valve
9
Flow inlet connection from the main EKHBRD indoor unit at
the bottom of the tank (quick coupling)
10
Return outlet connection to the main EKHBRD indoor unit at
the bottom of the tank (quick coupling)
1
Decoration panel
2
Quick fixation hole
3
Fasten with 2 screws
2x
2x
2x
2x
1
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
Содержание EKHTSU200AA