EK260AA + EKUHWHTA
Domestic hot water tank with UK kit for air to water heat pump system
4PW53247-1B
Installation manual
5
4 Put the sleeve on the valve and turn the valve so that the
sleeve is positioned according to the figure below.
5 Install the 3-way valve body in the pipework.
Refer to the figure below before making the connection.
6 Push the motor on the sleeve.
Make sure not to rotate the sleeve during this action, so as to
maintain the valve position as set during step
7 Put the turn knob on the valve motor cover as shown below.
Make sure that the turn knob is completely pushed in to allow
the turn knob being operated automatically by the unit. If the
turn knob is lifted slightly, manual operation is possible.
8 Make sure to firmly fix the power supply cord onto the 3-way
valve body with a field supplied cable tie like in illustration
below.
9 Perform the wiring in the indoor unit switch box in accordance
with the following figure: (make sure power supply is
switched off)
Make sure to follow the appropriate wiring routing inside of
the unit (this wiring routing can be found in the installation
manual of the indoor unit).
Refer also to the wiring diagram delivered with the indoor
unit.
5
Remove the top front decoration panel of the tank module as
indicated in the figure below.
If the valve is not positioned in this way before mount-
ing the motor, the valve will give way to both domestic
water and room heating during operation.
45
45
°
45
°
45
°
45
45
°
45
°
1
3
5
6
A
2
A
8
4
7
Room heating
Domestic hot water tank
X2M
3
4
5
3-way valve
BLU
BLK
BRN
N
Y
L
2x
Содержание EKHTSU200AA