background image

Operation manual

9

EKHBH/X016BA

Indoor unit for air to water heat pump system and options

4PW54186-1

Programming space heating or space cooling is carried out as
follows:

1

Use the 

=

  button to select the operation mode (heating or

cooling) you want to program.

2

Press the 

<

 button.

The actual mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to consult or to program by means
of the 

pi

 and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

 button to confirm the selected day.

The first programmed action of the selected day appears.

6

Use the 

pi

  and 

pj

  buttons to consult the other

programmed actions of that day.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.

7

Press the 

<

  button for 5 seconds to enter the programming

mode.

8

Use the 

<

 button to select the action number you would like to

program or to modify.

9

Use the 

ba

 button to select:

-

x

: to switch heating or cooling and the controller off.

-

9

: set the temperature by means of the 

bi

 and 

bj

 buttons.

-

a

: to select automatic temperature calculation (only in 

heating mode).

10

Use the 

pi

 and 

pj

 buttons to set the correct action time.

11

Repeat steps 

8

  to 

10

  to program the other actions of the

selected day.

When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.

12

Press the 

<

  button for 5 seconds to store the programmed

actions.

If the 

<

  button is pressed when action number 3 is displayed,

actions 1, 2 and 3 are stored but 4 and 5 are deleted.

You automatically return to step 

6

.

By pressing the 

pr

 button several times, you return to previous

steps in this procedure and finally return to normal operation.

Programming quiet mode, booster heating or domestic water
heating

Programming domestic water heating, booster heater or quiet mode
is carried out as follows:

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to program (quiet mode 

s

, booster heating 

m

  or domestic

water heating 

w

).

The selected mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The first programmed action is displayed.

4

Use the 

pi

  and 

pj

  buttons to consult the programmed

actions.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.

5

Press the 

<

  button for 5 seconds to enter the programming

mode.

6

Use the 

<

 button to select the action number you would like to

program or to modify.

7

Use the 

pi

 and 

pj

 buttons to set the correct action time.

8

Use the 

ba

 button to select or deselect 

x

 as action.

9

Repeat steps 

6

 to 

8

 to program the other actions of the selected

mode.

When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.

Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the

pr

 button.

Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the

pr

 button.

Содержание EKHBH016BA

Страница 1: ...OPERATION MANUAL EKHBH016BA EKHBX016BA Indoor unit for air to water heat pump system and options...

Страница 2: ...to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators...

Страница 3: ...rmostat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set poin...

Страница 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Страница 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Страница 6: ...turns to space heating operation Space cooling operation c In this mode cooling will be activated as required by the water temperature set point Domestic water heating operation w In this mode the ind...

Страница 7: ...n 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the dom...

Страница 8: ...rammed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to k...

Страница 9: ...nt Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with the default heating set point The set points of these automatically...

Страница 10: ...nds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the p...

Страница 11: ...ram it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press th...

Страница 12: ...ep 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface butt...

Страница 13: ...2 Start time time of the day at which the domestic hot water should be heated 2 03 Set point high water temperature to be reached 2 04 Interval time period defining how long the set point temperature...

Страница 14: ...not change this setting Leave it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refe...

Страница 15: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 35 14 35 1 C 03 Installation related setting...

Страница 16: ...O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weathe...

Страница 17: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Страница 18: ...NOTES NOTES...

Страница 19: ......

Страница 20: ...4PW54186 1 Copyright Daikin...

Отзывы: