background image

 

Operation manual

 

1

 

EKHBH/X016BA

 

Indoor unit for air to water heat pump system and options

 

4PW54186-1

 

C

 

ONTENTS

 

Page

 

Introduction ..................................................................................... 1

 

This manual ............................................................................................... 1
General information ................................................................................... 1
Safety considerations ................................................................................ 2

 

Operating the unit ........................................................................... 2

 

Introduction ....................................................................................... 2

Operating the digital controller .......................................................... 3

 

Features and functions .............................................................................. 3

Basic controller functions ...................................................................... 3
Clock function........................................................................................ 3
Schedule timer function......................................................................... 3

Name and function of buttons and icons ................................................... 3
Setting up the controller............................................................................. 5

Setting the clock .................................................................................... 5
Setting the schedule timer..................................................................... 5

Description of the operation modes ........................................................... 5

Space heating operation (

 

h

 

) ................................................................. 5

Space cooling operation (

 

c

 

) ................................................................. 5

Domestic water heating operation (

 

w

 

) ................................................. 5

Quiet mode operation (

 

s

 

).................................................................... 5

Controller operations ................................................................................. 6

Manual operation................................................................................... 6
Schedule timer operation ...................................................................... 7

Programming and consulting the schedule timer....................................... 8

Getting started....................................................................................... 8
Programming......................................................................................... 8
Consulting programmed actions.......................................................... 10
Tips and tricks ..................................................................................... 10

 

Field settings ................................................................................... 11

 

Procedure ................................................................................................ 11
Detailed description ................................................................................. 11
Field settings table................................................................................... 14

 

Maintenance .................................................................................. 16

 

Important information regarding the refrigerant used .............................. 16
Maintenance activities ............................................................................. 16
Standstill .................................................................................................. 16

 

Troubleshooting ............................................................................ 16

Disposal requirements ................................................................. 16

 

The English text is the original instruction. Other languages are
translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.

 

I

 

NTRODUCTION

 

This manual

 

This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.

 

General information

 

Thank you for purchasing this indoor unit.

The unit is the indoor part of the air to water ERHQ or ERLQ heat
pumps. These units are designed for wall mounted indoor installation.
The units can be combined with Daikin fan coil units, floor heating
applications, low temperature radiators, Daikin domestic water
heating applications and solar kit for domestic hot water applications.

 

Heating/cooling units and heating only units

 

The unit range consists of two main versions: a heating/cooling
(EKHBX) version and a heating only (EKHBH) version.

Both versions are delivered with an integrated backup heater for
additional heating capacity during cold outdoor temperatures. The
backup heater also serves as a backup in case of malfunctioning of
the outdoor unit. The backup heater models are available for a
heating capacity of 3, 6 and 9 kW, and – depending on the heating
capacity – for three different power supply specifications.

 

Domestic hot water tank (option)

 

An optional EKHW* domestic hot water tank with integrated 3 kW
electrical booster heater can be connected to the indoor unit. The
domestic hot water tank is available in three sizes: 150, 200 and
300 litre.

 

Solar kit for domestic hot water tank (option)

 

For information concerning the EKSOLHW solar kit, refer to the
installation manual of that kit.

 

Remote thermostat kit (option)

 

An optional room thermostat EKRTW, EKRTWA, or EKRTR can be
connected to the indoor unit. Refer to the installation manual of the
room thermostat for more information.

 

EKHBH016BA***
EKHBX016BA***

 

Indoor unit for air to water heat pump system 

and options

 

Operation manual

 

READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN
YOUR FILES FOR FUTURE REFERENCE.

 

Before operating the unit, make sure the installation has
been carried out correctly by a professional Daikin dealer.

If you feel unsure about operation, contact your Daikin
dealer for advice and information.

 

Indoor unit model

Backup heater capacity

Backup heater 

nominal voltage

EKHB*016BA3V3

 

3 kW

1x 230 V

 

EKHB*016BA6V3

 

6 kW

1x 230 V

 

EKHB*016BA6WN

 

6 kW

3x 400 V

 

EKHB*016BA9WN

 

9 kW

3x 400 V

 

EKHB*016BA6T1

 

6 kW

3x 230 V

 

EKHB*016BA9T1

 

9 kW

3x 230 V

Содержание EKHBH016BA

Страница 1: ...OPERATION MANUAL EKHBH016BA EKHBX016BA Indoor unit for air to water heat pump system and options...

Страница 2: ...to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators...

Страница 3: ...rmostat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set poin...

Страница 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Страница 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Страница 6: ...turns to space heating operation Space cooling operation c In this mode cooling will be activated as required by the water temperature set point Domestic water heating operation w In this mode the ind...

Страница 7: ...n 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the dom...

Страница 8: ...rammed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to k...

Страница 9: ...nt Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with the default heating set point The set points of these automatically...

Страница 10: ...nds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the p...

Страница 11: ...ram it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press th...

Страница 12: ...ep 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface butt...

Страница 13: ...2 Start time time of the day at which the domestic hot water should be heated 2 03 Set point high water temperature to be reached 2 04 Interval time period defining how long the set point temperature...

Страница 14: ...not change this setting Leave it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refe...

Страница 15: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 35 14 35 1 C 03 Installation related setting...

Страница 16: ...O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weathe...

Страница 17: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Страница 18: ...NOTES NOTES...

Страница 19: ......

Страница 20: ...4PW54186 1 Copyright Daikin...

Отзывы: