Installation manual
55
EKHBH/X008BB
Indoor unit for air to water heat pump system
4PW62570-1A – 01.2011
[8] Domestic water heating mode timer
■
[8-03] Booster heater delay time: This field setting is not
applicable for installations with restricted power supply
condition mode.
[C]
Additional external backup heater permission signal
[C-02]=2
This field setting is not applicable for installations with restricted
power supply condition mode.
[d] Restricted power supply condition mode/Local shift value
weather dependent
■
[d-00] and [d-01] are not applicable for installations with
restricted power supply condition mode.
■
[d-02] shall be set to 1 to activate the total restricted power
consumption.
Do not change this value.
Local shift value weather dependent
The local shift value weather dependent field setting is only relevant
in case weather dependent set point (see field setting
dependent set point" on page 27
■
[d-03] Local shift value weather dependent: determines the
shift value of the weather dependent set point around
outdoor temperature of 0°C.
T
t
Target water temperature
T
A
Outdoor temperature
R
Range
L
Local shift value
[1-00]~[1-04]
Applicable field settings of the weather dependent set
point [1].
[d-03]
Outdoor temperature range
(T
A
)
Local shift value
0
—
—
1
–2°C~2°C
2
2
4
3
–4°C~4°C
2
4
4
A
PPENDIX
(for restricted power supply condition mode only)
T
A
T
t
[1-03]
[1-00]
0
°
C
[1-01]
[1-02]
L
R