7.7.3
Water pressure
[→ Main menu → Information → Pressure]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Water pres-
sure
0 - 4 bar
The current water pressure is displayed in bar.
-
0.1 bar
S
S
Tab. 7-30
Parameter in menu: "Water pressure"
7.8
Error
[→ Main menu → Error]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Emergency
operation
Emergency heating by backup heater or another external heat generator.
-
E
E
No
Yes: In the event of an error, emergency operation is automatically activ-
ated.
Yes
No: In the event of an error, emergency operation by manual activation
only.
Manual oper-
ation status
Inactive
Activation of the fixed feed temperature control (for diagnostic purposes).
-
E
E
Active
Temperature,
manual oper-
ation
20 - 80 °C
Required feed temperature for manual operation.
50 °C
-
E
E
Tab. 7-31
Parameter in menu: "Error"
7.9
Terminal
[→ Main menu → Terminal]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Terminalad-
ress
Off
Setting of the terminal ID of the control panel for system access. The set
value must be unique throughout the entire system. Confirmation of this
parameter with the rotary button effects a new initialisation of the control
unit.
All settings except "Off", authorise the user of the control panel to activate
the terminal function and thus to operate all RoCon system components
with a valid device ID.
Off
1
N
E
0 - 9
Bus - Scan
Off
No function
Off
-
E
E
On
Control unit checks which RoCon devices are connected in the system via
CAN bus lines. Detected devices are displayed in the menu [→ Main menu
→ Terminal] with type and data bus ID (e.g. MM#8 = mixer module with
bus ID 8).
Contr BM1/
BE1 #X
With a detected device only: Activation switches to the heat generator with
the bus ID X (see
, [BUS ID HS] parameter).
-
Mix Valve #X
With a detected device only: Activation switches to the mixer module with
the bus ID X (see
, [Heating circuit assignment] parameter).
-
E
E
Tab. 7-32
Parameter in menu: "Terminal"
Содержание EHSHB04P30D
Страница 2: ......
Страница 354: ...11 Indice analitico Istruzioni per l uso 64 Daikin RoCon HP Daikin Regolazione RoCon HP 008 1444299_01 09 2018 IT...
Страница 530: ...11 Seznam hesel N vod k provozu 60 Daikin RoCon HP Daikin Regulace RoCon HP 008 1444299_01 09 2018 CS...
Страница 531: ...11 Seznam hesel N vod k provozu 61 Daikin RoCon HP Daikin Regulace RoCon HP 008 1444299_01 09 2018 CS...
Страница 532: ...008 1444299_01 09 2018 EN DE FR NL ES IT PT SV CS Copyright Daikin...