E(D/B)(H/L)Q011~0W1

 

Unit for air to water heat pump system

 

4PW57622-1

 

Operation manual

 

4

 

6.

 

CLOCK DISPLAY 

 

8

 

The clock display shows the current time.

When reading or programming the schedule timer, the clock
display shows the action time.

 

7.

 

SCHEDULE TIMER ICON 

 

p

 

This icon indicates that the schedule timer is enabled.

 

8.

 

ACTION ICONS 

 

q

 

These icons indicate the programming actions for each day of
the schedule timer.

 

9.

 

OFF ICON 

 

x

 

This icon indicates that the OFF action is selected when
programming the schedule timer.

 

10.

 

INSPECTION REQUIRED 

 

k

 

 and 

 

l

 

These icons indicate that inspection is required on the
installation. Consult your dealer.

11. SET TEMPERATURE DISPLAY 

9

The display shows the current set temperature of the
installation.

12. SETTING 

$

Not used. For installation purposes only.

13. NOT AVAILABLE 

n

This icon is displayed whenever a non-installed option is
addressed or a function is not available.

14. DEFROST/STARTUP MODE ICON 

d

This icon indicates that the defrost/startup mode is active.

15. COMPRESSOR ICON 

ç

This icon indicates that the compressor in the unit is active.

16. BACKUP HEATER STEP ONE 

(

 OR STEP TWO 

§

These icons indicate that the backup heater of the unit is
operating, when there is a high demand for heating capacity.
The backup heater provides extra heating capacity in case of
low ambient outdoor temperature (high heating load).

17. BOOSTER HEATER ICON 

m

This icon indicates that the booster heater is active. The booster
heater provides auxiliary heating for the domestic hot water
tank.

The booster heater is located in the domestic hot water tank.

The icon is not used when the domestic hot water tank is not
installed.

18. PUMP ICON 

é

This icon indicates that the circulation pump is active.

19. OUTDOOR TEMPERATURE DISPLAY 

u

When this icon is flashing, the outdoor ambient temperature is
displayed.

20. WEATHER DEPENDENT SET POINT ICON 

a

This icon indicates that the controller will adapt the temperature
set point automatically, based on the outdoor ambient
temperature.

21. TEMPERATURE ICON 

b

This icon is displayed when the water outlet temperature of the
unit, the outdoor ambient temperature and the domestic hot
water tank temperature are shown.

The icon is also displayed when the temperature set point is set
in schedule timer programming mode.

22. TEST OPERATION ICON 

t

This icon indicates that the unit runs in test mode. Refer to the
installation manual.

23. FIELD SET CODE 

;

This code represents the code from the field set list. Refer to the
installation manual.

24. ERROR CODE 

:

This code refers to the error code list and is for service purposes
only. Refer to the installation manual.

25. SPACE HEATING/COOLING BUTTON 

=

This button allows manual switching between cooling or heating
mode (provided the unit is not a heating only unit).

When the unit is connected with an external room thermostat,
this button is not operable and the icon 

e

 is shown.

26. DOMESTIC WATER HEATING BUTTON 

v

This button enables or disables heating of the domestic water.

This button is not used when the domestic hot water tank is not
installed.

27. WEATHER DEPENDENT SET POINT BUTTON 

ba

This button enables or disables the weather dependent set point
function which is available in space heating operation only.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 11

), the weather dependent set point button

will not be operable.

28. INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to 

"Field settings" on page 11

.

29. PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

30. SCHEDULE TIMER BUTTON 

r

/

p

The main function of this multi-purpose button is to
enable/disable the schedule timer.

The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.

If the controller is set in permission level 3 (refer to 

"Field

settings" on page 11

), the schedule timer button will not be

operable.

31. TIME ADJUST BUTTON 

pi

 and 

pj

These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
unit, outdoor ambient temperature and domestic hot water
temperature) and in schedule timer programming mode.

32. TEMPERATURE ADJUST BUTTONS 

bi

 and 

bj

These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.

33. DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS

wbi

 and 

wbj

These buttons are used to adjust the current set point of the
domestic hot water temperature.

The buttons are not used when the domestic hot water tank is
not installed.

34. QUIET MODE BUTTON 

s

This button enables or disables quiet mode.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 11

), the quiet mode button will not be

operable.

NOTE

Remark that pushing the 

y

 button has no influence

on the domestic water heating. Domestic water
heating is only switched on or off by means of the 

v

button.

Содержание EBHQ011BA6V3

Страница 1: ...DHQ016BA6W1 EDLQ011BA6V3 EDLQ014BA6V3 EDLQ016BA6V3 EDLQ011BA6W1 EDLQ014BA6W1 EDLQ016BA6W1 EBHQ011BA6V3 EBHQ014BA6V3 EBHQ016BA6V3 EBHQ011BA6W1 EBHQ014BA6W1 EBHQ016BA6W1 EBLQ011BA6V3 EBLQ014BA6V3 EBLQ016BA6V3 EBLQ011BA6W1 EBLQ014BA6W1 EBLQ016BA6W1 Unit for air to water heat pump system ...

Страница 2: ...ly units The monoblock unit range consists of two main versions a heating cooling EB version and a heating only ED version Both versions are delivered with an integrated backup heater for additional heating capacity during cold outdoor temperatures The backup heater also serves as a backup in case of malfunctioning of the unit and for freeze protection of the outside water piping during winter tim...

Страница 3: ...room thermostat connected to the unit This will prevent excessive space heating and will stop the unit and the circulation pump when the room temperature is above the thermostat set point Next recommendations only apply to installations with an optional domestic hot water tank Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low dome...

Страница 4: ...ive 3 OPERATION MODE ICONS hcws These icons indicate the current operation mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mode icons will be displayed simultaneously In a heating only installation the c icon will never be displayed If the domestic hot water ...

Страница 5: ...ce purposes only Refer to the installation manual 25 SPACE HEATING COOLING BUTTON This button allows manual switching between cooling or heating mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat this button is not operable and the icon e is shown 26 DOMESTIC WATER HEATING BUTTON v This button enables or disables heating of the domestic wa...

Страница 6: ...r tank by heat pump when the space heating space cooling operation has reached its temperature set point or heat pump domestic water heating has a higher demand request than space side depends on DIP switch setting When necessary and when allowed by the booster heater schedule timer refer to Programming quiet mode booster heating or domestic water heating on page 9 the booster heater provides auxi...

Страница 7: ... v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the domestic hot water is reached Selecting quiet mode operation s 1 Use the s button to activate quiet mode operation s Icon s appears on the display If the controller is set in permission level 2 or 3 refer to Fiel...

Страница 8: ...mmed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 10 Only use...

Страница 9: ...oint Conversely when programming cooling actions time and setpoint heating actions are added automatically at the same time but with the default heating set point The set points of these automatically added actions can be adjusted by programming the corresponding mode This means that after programming heating you should also program the corresponding cooling set points and vice versa Programming P...

Страница 10: ...store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the pr button several times you return to previous steps in this procedure and finally return to normal operation Programming quiet mode booster heating or domestic water heating Programming domestic water heatin...

Страница 11: ...is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the button to...

Страница 12: ...p 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface buttons can be made unavailable for the user Three permission levels are defined see the table below Switching between level 1 and level 2 3 is done by simultaneously pressing buttons pfi and pfj immediate...

Страница 13: ... whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic water should be heated 2 03 Set point high water temperature to be reached 2 04 Interval time period defining how long the set point temperature should be maintained 3 Auto restart When power returns after a power supply failure the auto restart function reapplies the user interface set...

Страница 14: ...his setting Leave it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refer to the installation manual of that kit D Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent s...

Страница 15: ...ace heating off temperature 35 14 35 1 C 03 Installation related setting 04 Installation related setting 5 Installation related settings 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting 6 Installation related settings 00 Installation related setting 01 Installation related setting 02 Inst...

Страница 16: ...lated setting 04 Installation related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3 4 E Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Read only 03 Liquid refrigerant temperature Read only C...

Страница 17: ...fied installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information DANGER Do not touch ...

Страница 18: ...NOTES NOTES ...

Страница 19: ......

Страница 20: ...Copyright Daikin 4PW57622 1 ...

Отзывы: