0 EKCBX/H008BAV3
Unit for air to water heat pump system
4PW64602-1A – 09.2010
Installation manual
47
19. U
NIT
SPECIFICATIONS
Technical specifications
Electrical specifications
(*)
European/International Technical Standard setting the limits for voltage
changes, voltage fluctuations and flicker in public low-voltage supply
systems for equipment with rated current
≤
75 A.
(**) European/International Technical Standard setting the limits for harmonic
currents by equipment connected to public low-voltage systems
with input current >16 A and
≤
75 A per phase
(***) System independence
Outdoor unit
EBHQ006BAV3
EBHQ008BAV3
Nominal capacity
• Cooling
(a)
(a) Only if connected to EKCBX008BAV3
Refer to the Technical Data
• Heating
Refer to the Technical Data
Dimensions H x W x D
(mm)
805 x 1190 x 360
Weight
• Machine weight
(kg)
95
• Operation weight
(kg)
99
Connections
• water inlet/outlet
1" MBSP
(b)
(b) MBSP = Male British Standard Pipe
Field installed waterpiping
• Minimum pressure
resistance
(bar)
4
• Minimim temperature
resistance
(°C)
65
• Recommended diameter
(inch)
1
Refrigerant
• Type
R410A
• Charge
(kg)
1.7
Expansion vessel
• Volume
(l)
6
• Pre-pressure
(bar)
1
• Maximum working pressure
(MWP)
(bar)
3.0
Pump
• Type
water cooled
• No. of speed
3
• Nominal ESP
• Cooling
(a)
(kPa)
49.7
45.8
• Heating
(kPa)
47.2
34.0
Sound level
• Sound power cooling
(a)
(dBA)
63
63
• Sound pressure cooling
(a)
(dBA)
48
50
• Sound power heating
(dBA)
61
62
• Sound pressure heating
(dBA)
48
49
Internal water volume
(l)
5.5
Pressure relief valve
water circuit
(bar)
3
Operation range - water side
• Heating
(°C)
+15~+50
• Cooling
(a)
(°C)
+5~+22
• Domestic hot water by heat
pump
(°C)
+25~+80
Operation range - air side
• Heating
(°C)
–15~+25
• Cooling
(°C)
+10~+43
• Domestic hot water by heat
pump
(°C)
–15~+35
Indoor unit
EKCBX008BAV3
EKCBH008BAV3
Dimensions H x W x D
(mm)
390 x 412 x 100
Weight
(kg)
6
Outdoor unit
EBHQ006BAV3
EBHQ008BAV3
Power circuit
• Phase
1~
• Frequency
(Hz)
50
• Voltage
(V)
230 (±10%)
Maximum running current
(a)
(a) Equipment complying with EN/IEC 61000-3-12 (**)
• Cooling
(b)
(b) Only if connected to EKCBX008BAV3
(A)
16.25
• Heating
(A)
18
Indoor unit
EKCBX008BAV3
EKCBH008BAV3
Power supply
(a)
(a) Above mentioned power supply is for the booster heater (EKW* option) and
backup heater kit (EKMBUH).
The switch box of the EKCB indoor unit is supplied via the outdoor unit.
The EKMBUH heater kit can be installed as a single step 3 kW heater or a 2 step
6 kW heater, for detailed information, refer to the heater kit installation manual.
• Phase
1~
• Frequency
(Hz)
50
• Voltage
(V)
230 (±10%)
• Running current (heater kit)
(A)
26
• Z
max
(heater kit + booster
heater (EKHWS* models))
(Ohm)
0.29
• Running current (heater kit +
booster heater (EKHWS* models)
• EK*V3
(A)
39 (26 + 13)
• EK*Z2
(A)
33.5
• Minimum S
SC
value
(b)
(b) In accordance with EN/IEC 61000-3-11 (*), it may be necessary to consult the
distribution network operator to ensure that the equipment is connected only to a
supply with Z
sys
(***)
≤
Z
max
• EK*V3
(kVA)
(c)
(c) Equipment complying with EN/IEC 61000-3-12 (**)
• EK*Z2
(kVA)
(c)
Operation range
• Ambient temperature
(°C)
5~35