Main
Menu
Option Menu
Active Alarm menu
(U U
(
xx
( xx: code numbers )
Last 6 Faults
/)
(
xx
( xx: code numbers )
Code Release Number
&U
CR Number
Reset to Factory Default
U )G
yes, no
Blower Speed for Continous Fan Mode
)6G
)
xx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 1st Stage
Compressor Mode
$&
)
xx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 2nd Stage
Compressor Mode
$&
)
xx
( xx: Blower Speed Number F01, F02.. )
Cool On Delay
&QG
Delay, Seconds
Default set at 7 Secs, Adjustments can
be made in 7 Secs increments from 0 to
35 Secs
Cool Off Delay
&I G
Delay, Seconds
Default set at 65 Secs, Adjustments
can be made in 5 Secs increments from
0 to 120 Secs
Blower Speed for Gas Heat Mode
J$)
)
xx
( xx: Blower Speed Number F01, F02.. )
Gas Heat On Delay
JQG
Delay, Seconds
Default set at 30 Secs, Adjustments
can be made in 5 Secs increments from
5 to 30 Secs
Gas heat Off Delay
J)G
Delay, Seconds
Default set at 90 Secs, Adjustments
can be made in 30 Secs increments from
30 to 180 Secs
Automatic Heat Staging - For Two
Stage Control
$+6
no, 10, 20, 30,
60, AUt
Refer to Section " CHANGING
HEATING MODE SETTING"
Menu Description
LED Display
Notes
1 Stage Status Codes