2 Safety instructions

Installation manual

4

D035A1/4AB + D035A4AB

Wall-mounted condensing boiler

3P469346-5N – 2019.11

CAUTION

Indicates a situation that could result in minor or moderate
injury.

NOTICE

Indicates  a  situation  that  could  result  in  equipment  or
property damage.

INFORMATION

Indicates useful tips or additional information.

1.2

Identification label

You  can  find  data  about  the  unit  on  its  identification  label,  which  is
located at the bottom of the right cover of the unit.

Pn (80/60)
Pn (50/30)
Qn
Qnw
D (

Δ

T=30 K)

PMS

PMW

Nox 

kW
kW
kW
kW
l/min

bar
MPa
bar
MPa

/

/

XXXX-XX

PIN: 

a

b

c

d

e

f

g
h

i

j

k

l

m

n

o

p

q

r

s

t

v

u

a

Product number

b

Electrical supply

c

Maximum electrical power consumption

d

Degree of protection

e

Nominal heat output range @ 80/60

f

Nominal heat output range @ 50/30

g

Nominal heat input range

h

Nominal heat input range (Domestic hot water)

i

Hot water amount @ DT=30

j

NOx class

k

Maximum central heating pressure (bar)

l

Maximum central heating pressure (MPa)

m

Maximum domestic hot water pressure (bar)

n

Maximum domestic hot water pressure (MPa)

o

Country of destination(s)

p

Serial number

q

Appliance type

r

Efficiency class

s

Gas category

t

Gas type and supply pressure

u

PIN number

v

Product type

1.3

Symbols on the package

This is a fragile piece of equipment: Please provide a dry
storage space for the unit.

This is a fragile piece of equipment: Please be very careful
not to drop.

Store the unit in a flat position as indicated on the box.

No more than 5 boxes should be stacked on top of each
other.

MAX. 2

When stacking 6 boxes on one pallet, no more than 2
pallets should be stacked on top of each other.

MAX. 3

When stacking 4 boxes on one pallet, no more than 3
pallets should be stacked on top of each other.

2

Safety instructions

These  instructions  are  exclusively  designed  for  qualified  competent
persons.

▪ Work  on  gas  units  must  only  be  carried  out  by  a  qualified  gas

fitter.

▪ Work  on  electrical  equipment  must  only  be  carried  out  by  a

qualified electrician.

▪ The  system  must  be  commissioned  by  a  qualified  competent

person.

WARNING

A  qualified  person  shall  explain  the  operating  principles
and the use of the unit to the user. The user is not allowed
to  perform  any  modifications,  maintenance  or  repairs  on
the  unit,  unless  otherwise  stated,  or  have  the  such
performed  by  unauthorised  third  parties.  Otherwise,  the
unit warranty becomes void.

DANGER

Isolate the boiler from the power mains before working on
it.

WARNING

Unit  installation,  commissioning,  repair,  configuration  and
service must be performed by qualified competent persons
in  accordance  with  local  standards  and  regulations.
Incorrect installation of this unit may harm the user and his/
her  surroundings.  The  manufacturer  is  not  responsible  for
any malfunctions and/or damage that may occur this way.

DANGER

Flammable  fluids  and  materials  must  be  stored  at  least
1 metre away from the boiler.

WARNING

To  ensure  faultless  operation,  long  term  availability  of  all
functions  and  long  working  life  of  the  boiler  only  use
original spares.

3

About the unit

This  Daikin  unit  is  a  wall-mounted  gas-fired  condensing  boiler  that
can  supply  heat  to  central  heating  systems,  as  well  as  supply
domestic hot water. Depending on settings, it is possible to use the
unit  solely  for  hot  water  or  solely  for  central  heating.  Hot  water
supply  type  can  be 

instantaneous

  or  by  means  of  a  hot  water

storage  tank

Heating  only

  boilers  do  not  supply  domestic  hot

water.  The  type  of  the  boiler  can  be  recognized  from  the  model
name written on the identification label. See table below:

Model

Type

Domestic hot water

supply

Filling loop

D2CND028A1AB D2CND028

Instantaneous

Internal

D2CND028A4AB D2CND028

Instantaneous

External

Содержание D2CND028A1AB

Страница 1: ...Installation manual Wall mounted condensing boiler English Installation manual Wall mounted condensing boiler D2CND028A1AB D2CND028A4AB D2CND035A1AB D2CND035A4AB D2TND028A4AB D2TND035A4AB...

Страница 2: ...tiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lie...

Страница 3: ...pressure 29 Disposal Old units must be appropriately disposed of in accordance with local and national regulations The components are easy to separate and the plastics are marked This allows the vario...

Страница 4: ...r 2 Safety instructions These instructions are exclusively designed for qualified competent persons Work on gas units must only be carried out by a qualified gas fitter Work on electrical equipment mu...

Страница 5: ...s preventing the pressure from rising Safety valve When the water pressure of the heating circuit exceeds 3 bar some water is automatically drained from the safety valve to keep the pressure below 3 b...

Страница 6: ...5A1 4AB D2TND028 035A4AB Wall mounted condensing boiler 3P469346 5N 2019 11 Bottom view of model D2CND028A4AB and D2CND035A4AB 90 65 65 68 65 37 5 125 132 180 Bottom view of models D2TND028A4AB and D2...

Страница 7: ...s Silencer t Automatic air vent pump u Water pressure sensor v By pass w Boiler pump x Domestic hot water flow sensor y Domestic hot water flow limiter z Internal filling valve included in model D2CN...

Страница 8: ...31 Consumption min max m h 0 2 1 09 0 2 1 38 0 2 1 09 0 2 1 38 Combustion products mass flow rate min max G20 g s 2 2 12 35 2 2 15 47 2 2 12 35 2 2 15 47 Combustion products mass flow rate min max G31...

Страница 9: ...heaters 50 C return temperature at heater inlet 4 Installation 4 1 To open the unit WARNING Only qualified competent persons are allowed to open the unit Certain actions explained in this document suc...

Страница 10: ...urrent I E E Wiring Regulations local Building Regulations or any other local regulations currently in service The intake air must not include chemicals that may cause corrosion toxic gas formation an...

Страница 11: ...pressure bar In case system charge pressure needs to be more than 1 bar gas side initial charge pressure must be increased to the pressure value that is equal to system charge pressure Make sure that...

Страница 12: ...g circuit 0 0 100 200 300 400 500 600 700 800 200 400 600 800 1000 1200 1400 1600 1800 A mbar B l h A Residual pump lift mbar B Flow l h 4 8 Connections NOTICE During installation do not loosen or rem...

Страница 13: ...he following instructions WARNING Ignoring the rules explained below may result in serious damages in installation or boiler or cause discomfort of the user The manufacturer is not responsible for any...

Страница 14: ...pacity or incomplete electrical work may cause electrical shock or fire A main switch or other means for disconnection having a contact separation in all poles providing full disconnection under overv...

Страница 15: ...able glands that are sent with the unit must be assembled to the bottom sheet of the boiler in case connection of these options Below you can see the cable glands placement PG9 PG7 PG7 PG9 Holes on th...

Страница 16: ...Wall mounted condensing boiler 3P469346 5N 2019 11 4 8 6 Wiring diagram DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes before servicing Models D2CND028A1AB D2CND028A...

Страница 17: ...Card Ext2 X10 Personal computer production interface Ext3 X1M Daikin room thermostat Ext4 X2M External power output 230 V AC Ext5 X2M Reserved not in use X1M X4 X11 X12 Low voltage terminal strip X2M...

Страница 18: ...vent backflow from common chimney Approved ue systems Choose a flue type according to the installation site Approved flue types are written on the identification label Flue termination The positions o...

Страница 19: ...nsible for atmospheric conditions when siting flue terminals CAUTION Once the flue system has been installed and the appliance commissioned the installer should observe the plume direction Particular...

Страница 20: ...rom the outside and expels flue gas to the outside through a concentric coaxial pipe via the roof The terminal outlets from separate combustion and air supply circuits shall fit inside a square of 50...

Страница 21: ...lowable length of the ue duct up to common chimney is 2 metres 1 60 100 90 elbow In C43x type units condensate flow into the unit is not allowed Type C63x concentric flue system INFORMATION C63 flue t...

Страница 22: ...mm 1 0 m Equivalent length of options 90 elbow 80 mm 2 0 m Subtract equivalent length value of bends from the allowable flue length value Note The air intake length is 3 metres In case of longer air...

Страница 23: ...circular and rough 130 11 6 34 1 Allowable flue length for C93x DN 80 Flex circular and rough 120 4 4 13 0 DN 80 Flex square and rough 140 23 8 69 9 DN 80 Flex square and rough 130 20 6 60 6 DN 80 Fle...

Страница 24: ...909 43 47 EKFGT6305 48 52 EKFGT6306 53 57 EKFGT6307 Flat roof outlet kit 60 100 EKFGP6940 80 125 EKFGW5333 Flue part Order code Wall bracket DN 100 EKFGP4631 DN 125 EKFGP4481 60 100 to 80 125 adapter...

Страница 25: ...filling pressure Filling operation should be done slowly When pressure exceeds 0 8 bar error code will disappear and the status indicator light will turn to blue Turn the valve 7 off 7 You can monito...

Страница 26: ...5 Commissioning WARNING Only qualified persons should conduct commissioning CAUTION Preliminary electrical system checks such as earth continuity polarity resistance to earth and short circuit must b...

Страница 27: ...the sweeper mode gas analyzer device should be mounted to its place on the flue 3 To activate the sweeper mode press Cancel and Menu buttons together 5 seconds With sweeper mode boiler can be operated...

Страница 28: ...s under the relevant national regulations Explain and demonstrate the lighting and shutting down procedures Explain the function and the use of the boiler heating and domestic hot water controls Expla...

Страница 29: ...person who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMI...

Страница 30: ...g co uk It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND...

Страница 31: ......

Страница 32: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P469346 5N 2019 11 Copyright 20...

Отзывы: