TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite:
Remove the front grille.
1
Remove 1 screw from the electrical wiring box.
2
Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
3
Unhook the tab(s) on the bottom and remove the electrical wiring box cover.
a
a
c
b
a
1
3
2
a
Tab
b
Protruding part on the top of the cover
c
Screw
To remove the switch box
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect the power supply wiring from the power supply terminal X1M.
2
Remove the screw and power supply wiring bracket.
3
Pull the clip and remove the heat exchanger thermistor from its holder.
4
Remove the screws to disconnect the grounding wires from the heat
exchanger.
a a
b
c
d
e
a
Grouding wire screw
b
Heat exchanger thermistor
c
Indoor unit PCB