3
|
Components
Service manual
122
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
8
Disconnect the thermistor from the intermediate connector and measure the
resistance of the thermistor (between the appropriate pins of the connector).
Does the measured resistance of the
thermistor match with the
temperature determined resistance?
Action
Yes
Correct the wiring between the
thermistor connector on the PCB and
the intermediate connector, see
No
Replace the specific thermistor, see
122].
Repair procedures
To remove the thermistor
Indoor unit air (room) thermistor
As the indoor unit air (room) thermistor is located on the display PCB, remove the
display PCB as described in the steps below:
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
100].
1
Disconnect the connector from the display PCB.
2
Press the latches to unlock and remove the display PCB from the unit.
3
To install the indoor unit air (room) thermistor, see
Other refrigerant side thermistors
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
100].
1
Locate the thermistor that needs to be removed.
2
Remove the thermistor from the thermistor holder as follows:
▪
For outdoor unit air (ambient) thermistor:
Open the thermistor holder and remove the thermistor from the holder.
▪
For refrigerant piping thermistors:
- Cut the tie straps that fix the insulation and the thermistor wire.
- Cut and remove the insulation.
- Pull the clip that fixes the thermistor.
- Remove the thermistor from the thermistor holder.