Drain Pump
Si091659E
22
Removal Procedure
8. Drain Pump
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the drip proof
plate (right).
1
Remove the screw of
the drip proof plate
(right).
2
Unfasten the hook.
3
Remove the drip proof
plate (right).
2. Remove the earth/ground
wire and the heat
exchanger thermistor.
1
Remove the screw of
the earth/ground wire.
Drip proof
plate (right)
(R23780)
Hook
(R10966)
(R10967)
Earth/ground wire
(R23781)