1
English
BYCQ140CGW1
Self Cleaning decoration panel
Installation
manual
CONTENTS
1. SAFETY
PRECAUTIONS
..........................................................1
2. ACCESSORY.............................................................................1
3. INSTALLATION
SITE
.................................................................2
4. PREPARATIONS FOR PANEL...................................................3
5. PREPARATIONS FOR INDOOR UNIT ......................................4
6. ATTACHING PANEL TO INDOOR UNIT ....................................5
7. ATTACHING SUCTION GRILLE
AND DECORATION CORNER COVERS ..................................7
8. OPERATION MODE SETTINGS .............................................10
9. FIELD
SETTINGS
....................................................................10
10. TEST OPERATION ..................................................................10
SAFETY PRECAUTIONS
1.
Please read these “SAFETY PRECAUTIONS” carefully before
installing air conditioning equipment and be sure to install it correctly.
After completing installation, conduct a trial operation to check for
faults and explain to the customer how to operate the air condi-
tioner and take care of it with the aid of the operation manual. Ask
the customer to store the installation manual along with the
operation manual for future reference.
This air conditioner comes under the term “appliances not
accessible to the general public”.
Meaning of WARNING and CAUTION notices.
WARNING
Failure to follow these instructions properly
may result in personal injury or loss of life.
CAUTION
Failure to observe these instructions properly
may result in property damage or personal
injury, which may be serious depending on
the circumstances.
WARNING
Ask your dealer or qualifi ed personnel to carry out installation
•
work.
Do not attempt to install the air conditioner yourself. Improper
installation may result in water leakage, electric shocks or fi re.
Perform installation work in accordance with the instructions in
•
this installation manual. Do not modify the product.
Improper installation may result in water leakage, electric shocks,
or fi re.
Be sure to use only the specifi ed accessories and parts for
•
installation work.
Failure to use the specifi ed parts may result in the unit falling,
water leakage, electric shocks or fi re.
Make sure that specifi ed wires are used and that there is no
•
strain on the terminal connections or wires.
Improper connections or securing of wires may result in
abnormal heat radiation or fi re.
Be sure to switch off the unit before touching any electrical parts.
•
Arrange the lead wires of the provided harness so that the EL.
•
COMPO. BOX lid of the indoor unit will not rise, and attach the lid
securely.
Heat radiation, electric shocks, or fi re may result if the EL.
COMPO. BOX lid is not attached properly.
Tear up and dispose of the plastic bag.
•
Children playing with the plastic bag may be suffocated.
CAUTION
Install the indoor and outdoor units, power cord, remote controller
•
wiring, and transmission wiring at least 1m away from TV or radio
sets. This is for the prevention of TV and radio interference.
(Depending on the incoming signal strength, a distance of
1 meter may not be suffi cient to eliminate noise.)
Pay the utmost attention to the transportation of the product.
•
Hold the handles on the package to carry the product.
Do not carry the package with the polypropylene band on the
package held, which will be dangerous because the polypropyl-
ene band may be deformed.
Do not touch the fi n of the heat exchanger.
•
Touching the fi n improperly may result in injury.
Do not turn the product power off immediately after the operation
•
of the product comes to a stop.
Always wait for at least 5 minutes before turning the product
power off.
Otherwise, water leakage and malfunctions may result.
Do not install the air conditioner in the following locations:
•
Where there is a high concentration of mineral oil spray or
1.
vapour (e.g. a kitchen).
Plastic parts will deteriorate, parts may fall off and water
leakage could result.
Where corrosive gas, such as sulphurous acid gas, is
2.
produced.
Corroding of copper pipes or soldered parts may result in
refrigerant leakage.
Near machinery emitting electromagnetic radiation.
3.
Electromagnetic radiation may disturb the operation of the
control system and result in a malfunction of the unit.
Where fl ammable gas may leak, where there is carbon fi bre or
4.
ignitable dust suspensions in the air, or where volatile
fl ammables such as paint thinner or gasoline are handled.
Operating the unit in such conditions may result in fi re.
[Instructions peculiar to this product]
Do not install the product in the following places.
Oil, cigarette tar, and steam will result in sticky dust on the fi lter,
which may not be cleaned properly. Furthermore, sticky dust may
cause malfunctions.
Places with oily smoke: Restaurants, factories, etc.
Places with excessive cigarette smoke: Smoking room, etc.
Places with excessive moisture or steam: Restaurants, factories,
etc.
The air conditioner is not intended for use in a potentially
•
explosive atmosphere.
Note
Have the customer actually operate the air conditioner while
•
referring to the operation manual and explain the right operation
of the air conditioner with useful tips given.
Refer to the operation manual along with the installation manual
•
provided with the indoor unit.
Use the BRC1E51A7 remote controller.
•
ACCESSORY
2.
Check that the following accessories provided with the air condi-
tioner are correct in number. See the following illustration, which
shows where the accessories are kept.
Backside of the protective
corrugated cardboard
A set of accessories
The accessories are
on the backside of the
protective corrugated
cardboard under
the suction grille.
Suction grille
01_EN_3P257556-1.indd 1
01_EN_3P257556-1.indd 1
9/3/2009 4:04:41 PM
9/3/2009 4:04:41 PM