Daikin BRC7EA628 Скачать руководство пользователя страница 7

English

5

19

RECEIVER

This receives the signals from the 
remote controller.

20

OPERATING INDICATOR LAMP (Red)

This lamp stays lit while the air 
conditioner runs. It flashes when the 
unit is in trouble.

21

TIMER INDICATOR LAMP (Green)

This lamp stays lit while the timer is set.

22

AIR FILTER CLEANING TIME 
INDICATOR LAMP (Red)

Lights up when it is time to clean the air 
filter.

23

DEFROST LAMP (Orange)

Lights up when the defrosting opera-
tion has started. (For cooling only type 
this lamp does not turn on.)

24

FAN/AIR CONDITIONING SELECTOR 
SWITCH

Set the switch to “

” (FAN) for FAN 

and “

” (A/C) for HEAT or COOL.

25

COOL/HEAT CHANGEOVER SWITCH

Set the switch to “

” (COOL) for 

COOL and “

” (HEAT) for HEAT.

NOTE

For the sake of explanation, all indica-
tions are shown on the display in Figure 1 
contrary to actual running situations.

Fig. 1-2 shows the remote controller with 
the front cover opened.

Fig. 1-3 shows this remote controller can 
be used in conjunction with the one pro-
vided with the VRV system.

If the air filter cleaning time indicator lamp 
lights up, clean the air filter as explained 
in the operation manual provided with the 
indoor unit.
After cleaning and reinstalling the air fil-
ter, press the filter sign reset button on 
the remote controller. The air filter clean-
ing time indicator lamp on the receiver 
will go out.

The Defrost Lamp will flash when the power 
is turned on. This is not a malfunction.

Precautions in handling remote con-

troller

Direct the transmitting part of the remote 
controller to the receiving part of the air 
conditioner.

If something blocks the transmitting and 
receiving path of the indoor unit and the remote 
controller, such as curtains, it will not operate.

2 short beeps from the receiver indicates 
that the transmission is properly done.
Transmitting distance is approximately 7 m.
Do not drop or get it wet.

It may get damaged.

Never press the button of the remote con-
troller with a hard, pointed object.

The remote controller may get damaged.

Installation site

It is possible that signals will not be received 
in rooms that have electronic fluorescent 
lighting. Please consult with the salesman 
before buying new fluorescent lights.

If the remote controller operated some 
other electrical apparatus, move that 
machine away or consult your dealer.

Placing the remote controller in the 
remote controller holder

Install the remote controller holder to a wall 
or a pillar with the attached screws. (Make 
sure it transmits)

3. Handling of wireless 

remote controller

3PEN505118-2B.book  Page 5  Thursday, January 7, 2021  10:28 AM

Содержание BRC7EA628

Страница 1: ...MODELS BRC7EA628 BRC7EA629 BRC7EA630 Wireless Remote Controller Kit OPERATION MANUAL 3PEN505118 2B book Page 1 Thursday January 7 2021 10 28 AM...

Страница 2: ...ST H M L MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF C hr hr TEST H M L BRC7EA628 BRC7EA629 BRC7EA630 6 BRC7EA628 BRC7EA629 BRC7EA630 24 25 COOL HEAT CHANGEOVER REMOTE CONTROL SW...

Страница 3: ...l in a conve nient place so that you can refer to it when ever necessary If the equipment is transferred to a new user be sure to hand over the manual as well WARNING Be aware that prolonged direct ex...

Страница 4: ...ON or OFF Otherwise fire or water leakage may result Furthermore the fan will rotate abruptly if power failure compensation is enabled which may result in injury Do not use the product in the atmo sph...

Страница 5: ...liance before it is scrapped and they are disposed of safely Arrange the drain to ensure complete drainage If proper drainage from the outdoor drain pipe does not occur during air conditioner operatio...

Страница 6: ...fan speed M H L C hr hr 7 DISPLAY INSPECTION TEST OPERATION When the INSPECTION TEST OPER ATION BUTTON is pressed the dis play shows currently set mode 8 ON OFF BUTTON Press the button and the system...

Страница 7: ...ter press the filter sign reset button on the remote controller The air filter clean ing time indicator lamp on the receiver will go out The Defrost Lamp will flash when the power is turned on This i...

Страница 8: ...ol it is necessary to switch the remote controller s set ting In this case contact your DAIKIN dealer VRV System See the operation manual provided with the air conditioner Refer to figure 1 on page 1...

Страница 9: ...DE SELECTOR ON OFF HEATING OPERATION FAN OPERATION DRY OPERATION See FOR SYSTEM WITHOUT COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH for details on dry operation 2 Press OPERATION MODE SELECTOR button s...

Страница 10: ...this button is pressed setting temperature shifts to L side C The setting is impossible for fan operation NOTE The setting temperature range of the remote controller is 16 C to 32 C ADJUSTMENT TEMPER...

Страница 11: ...e stop time can be simulta neously programmed Operation mode Cooling Heating Operation conditions When operating continuously at downward air flow direction When room temperature is higher than the se...

Страница 12: ...very system When one BS unit is connected with several indoor units Only the master remote controller can select HEATING COOLING or AUTOMATIC only Heat recovery system OPERATION When the indoor unit w...

Страница 13: ...ne indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally...

Страница 14: ...the following steps yourself to read the malfunction code that appears on the dis play Contact your dealer with this code It will help pinpoint the cause of the trouble speed ing up the repair Press t...

Страница 15: ...7 ON OFF 2 4 6 Operate the indoor unit with the remote con troller of the same number Signal transmitted from a remote controller of a different number cannot be accepted If the number is not mentione...

Страница 16: ...mbol can be printed beneath the symbol This chemical symbol means that the battery contains a heavy metal above a certain con centration Possible chemical symbols are Pb lead 0 004 Do not try to disma...

Страница 17: ...3PEN505118 2B book Page 1 Thursday January 7 2021 10 28 AM...

Страница 18: ...3PEN505118 2B book Page 2 Thursday January 7 2021 10 28 AM...

Страница 19: ...3PEN505118 2B book Page 3 Thursday January 7 2021 10 28 AM...

Страница 20: ...3P505118 2B 2020 10 Copyright 2017 Daikin 3PEN505118 2B book Page 1 Thursday January 7 2021 10 28 AM...

Отзывы: