background image

OH12-01

Remote Controller (Wireless Type)

Control Systems

171

2

3P107422-1S

English

14

II.

  IN CASE BESIDES EMERGENCY STOP

1. The unit does not operate at all.

Check if the receiver is exposed of 
sunlight or strong light. Keep receiver 
away from light.

Check if there are batteries in the 
remote controller. Place the batteries.

Check if the indoor unit number and 
wireless remote controller number are 
equal.

Operate the indoor unit with the remote con-
troller of the same number.
Signal transmitted from a remote controller of 
a different number cannot be accepted. (If 
the number is not mentioned, it is considered 
as “1”)

2. The system operates but it does not 

sufficiently cool or heat.

If the set temperature is not proper.

If the FAN SPEED is set to LOW 
SPEED.

If the air flow angle is not proper.

Contact the place of purchase in the fol-
lowing case.

WARNING

When you detect a burning odor, shut 
OFF power immediately and contact the 
place of purchase. Using the equipment 
in anything but proper working condition 
can result in equipment damage, electric 
shock and/or fire.

Number

Number

[

Trouble]

The RUN lamp of the indoor unit is flashing 
and the unit does not work at all.

[Remedial action]

Check the malfunction code (A1 - UF) on the 
remote controller.
Notify and inform the model name and what 
the malfunction code indicates to your Daikin 
dealer.

MODE

TIMER

RESERVE CANCEL

DOWN

UP

/TEST

SWING

FAN

TIME

TEMP

ON OFF

UNIT N

O

.

CODE

Malfunction Code

Unit No. which
sensed trouble

INSPECTION
display

1

.8

  B

R

C

7

E

5

3

0

W

 / 

B

R

C

7

E

5

3

1

W

Содержание BRC7E530W

Страница 1: ...Remote Controller Wireless Type OH12 01 156 Control Systems 1 8 BRC7E530W BRC7E531W for FXZQ 1 8 1 Features 1 8 2 Dimensions Unit mm 3D038937A...

Страница 2: ...3P107422 1S 1 1 1 2 8 10 13 11 12 15 14 16 17 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr hr TEST 1 24 25 COOL HE...

Страница 3: ...he manual WARNING Be aware that prolonged direct expo sure to cool or warm air from the air conditioner or to air that is too cool or too warm can be harmful to your phys ical condition and health Whe...

Страница 4: ...ating the air conditioner with the power supply breaker turned ON or OFF Otherwise fire or water leakage may result Furthermore the fan will rotate abruptly if power failure compensation is enabled wh...

Страница 5: ...rs may explode because the warm air output of the indoor or outdoor unit will affect them The batteries must be removed from the appliance before it is scrapped and they are disposed of safely Arrange...

Страница 6: ...IR FLOW FLAP Refer to page 9 6 DISPLAY FAN SPEED The display shows the set fan speed M H L C hr hr 7 DISPLAY INSPECTION TEST OPERATION When the INSPECTION TEST OPER ATION BUTTON is pressed the display...

Страница 7: ...ed in the operation manual provided with the indoor unit After cleaning and reinstalling the air fil ter press the filter sign reset button on the remote controller The air filter clean ing time indic...

Страница 8: ...t use new and old batteries intermixed In case the remote controller is not used for a long time take out all batteries in order to prevent liquid leak of the battery IN THE CASE OF CENTRALIZED CONTRO...

Страница 9: ...DE SELECTOR button several times and select the OPERATION MODE of your choice as follows COOLING OPERATION HEATING OPERATION 5 OPERATION PROCEDURE COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATI...

Страница 10: ...eling cold use another heater at the same time as this air conditioner 2 ON OFF Hot air is circulated to warm the room It will take some time from when the air con ditioner is first started until the...

Страница 11: ...ons micro computer controls the air flow direction so it may be different from the display NOTES If you try cooling or programmed drying while the flaps are facing downward air flow direction may chan...

Страница 12: ...For example When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system will stop after 3 hours and then 1 hour later the sys tem will start 1 TIMER 2 D...

Страница 13: ...roller Operate in the following order One of these remote controllers needs to be designated as the master remote controller Outdoor unit Indoor unit BS unit Continuously press the OPERATION MODE SELE...

Страница 14: ...lowing symptoms do not indicate air conditioner malfunction I THE SYSTEM DOES NOT OPERATE The system does not restart immediately after the ON OFF button is pressed If the OPERATION lamp lights the sy...

Страница 15: ...N MODE SELECTOR BUTTON on the left hand of the malfunction code blinks Press PROGRAMMING TIMER BUT TON and change the malfunction code Press until the indoor unit beeps twice 1 TEST 2 DOWN UP 3 6 3 6...

Страница 16: ...sufficiently cool or heat If the set temperature is not proper If the FAN SPEED is set to LOW SPEED If the air flow angle is not proper Contact the place of purchase in the fol lowing case WARNING Wh...

Страница 17: ...n symbols CAUTION If the caution is not observed it may cause injury or damage to equipment NOTE These instructions will ensure proper use of the equipment CAUTION Refer also to the installation manua...

Страница 18: ...e remote controller in the direction of the receiver The direct transmitting distance of the remote controller is approximately 7 meters The signal cannot be transmitted if something such as curtains...

Страница 19: ...he installation manual attached to the indoor unit Be sure to turn off power before removing the control box lid 2 Determination of address and MAIN SUB remote controller If setting multiple wireless...

Страница 20: ...e the multiple setting as shown below 3 Stick the Unit No label on the air outlet of the decoration panel and the back of the wireless remote controller PRECAUTIONS Set the Unit No of the receiver and...

Страница 21: ...rom the receiver on the upper part of the panel temporary suspension of the decoration panel Be sure to push the harness to the groove 3 Attach the decoration panel to the indoor unit Refer to the ins...

Страница 22: ...um of four seconds and the FIELD SET MODE is entered 2 Select the desired MODE NO with the button 3 Push the button and select the FIRST CODE NO 4 Push the button and select the SECOND CODE NO 5 Push...

Страница 23: ...OF SETTING SECOND CODE NO NOTE 01 02 03 10 0 Filter Contamination Heavy Light Setting for spacing time of dis play time to clean air filter Setting for when filter contamination is heavy and spacing t...

Страница 24: ...l attached to the indoor unit if it does not operate 2 Refer to the installation manual attached to the outdoor unit for individual operation system types Order Operation 1 Open gas side stop valve 2...

Отзывы: