5.

FIELD SETTING

If optional accessories are mounted on the indoor unit, the 
indoor unit setting may have to be changed. Refer to the instruc-
tion manual (optional hand book ) for each optional accessory.

Procedure

(1) When in the normal mode, press the “

” but-

ton for at least 4 seconds, and the FIELD SET MODE is  
entered.

(2) Select  the desired MODE NO. with the “

” button.

(3) Push the “

” button and select the FIRST CODE NO..

(4) Push the “

” button and select the SECOND CODE 

NO..

(5) Push the“

”button and the  present settings 

are set.

(6) Push the “

” button to quit the FIELD SET 

MODE and return to the normal display.

(Example) If the time to clean air filter is set to “Filter Con-

tamination-Heavy”, set Mode No. to “10”, FIRST 
CODE NO. to "0", and SECOND CODE NO. to 
“02”.

NOTE

The SECOND CODE NO. is factory set to "01".
Do not use any settings not listed in the table.
For group control with a wireless remote controller, initial set-
tings for all the indoor units of the group are equal. (For group 
control, refer to the installation manual attached to the indoor 
unit for group control.)

6.

TEST OPERATION

• Perform test operation according to the instructions in the 

installation manual attached to the indoor unit.

• After refrigerant piping, drain piping, and electric wiring, 

operate according to the table to protect the unit.

CAUTION

1. Refer to a malfunction code in the installation manual 

attached to the outdoor unit if it does not operate.

2. Refer to the installation manual attached to the outdoor unit 

for individual operation system types.

MODE 

NO.

FIRST 
CODE 

NO.

DESCRIPTION OF SETTING

10

0

Filter Contamination-Heavy/Light 
(Setting for spacing time of display 
time to clean air filter) (Setting for 
when filter contamination is heavy, 
and spacing time of display time to 
clean air filter is to be halved)

Long-life type

Standard type

3

Spacing time of display time to clean air filter count 
(Setting for when the filter sign is not to be displayed)

12 

(VRV 

system)

1

ON/OFF input from outside (Set to enable starting/
stopping from remote.)

2

Thermostat differential changeover (Set when using 
remote controller thermostat sensor.)

MODE

TIMER

RESERVE CANCEL

DOWN

UP

 TEST

FAN

TIME

TEMP

ON OFF

SETTING

MODE NO.

SECOND CODE NO.

FIRST CODE NO.

FIELD SET MODE

(3)

(5)

(2)

(1) (6)

(4)

TEST

MODE

UP

DOWN

RESERVE

TEST

MODE 

NO.

FIRST 
CODE 

NO.

SECOND CODE NO.

01

02

03

10

0

Light

Approx. 
2,500 hours

Heavy

Approx. 
1,250 hours

Approx. 200 
hours

Approx. 100 
hours

3

Display

Do not display

12 

(VRV 

system)

1

Forced OFF input 

ON/OFF

2

2°F

1°F

Order

Operation

(1)

Open gas side stop valve. 

(2)

Open liquid side stop valve.

(3)

Electrify crank case heater for 6 hours.

(4)

Set to cooling with the remote controller and push “

” 

button to start operation.

(5)

Push“

”button twice and operate in TEST OPERA-

TION MODE for 3 minutes.

(6)

Push“

”button and confirm its operation.

(7)

Push“

”button and operate normally.

(8)

Confirm its function according to the operation manual.

ON/OFF

TEST

SWING

TEST

Содержание BRC4C82

Страница 1: ...82 INSTALLATION MANUAL Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should be left with the equipment owner Wireless Remote Controller Kit ...

Страница 2: ... electric shock CAUTION Refer also to the installation manuals attached to the indoor unit and the decoration panel Confirm that the following conditions are satisfied prior to installation Ensure that nothing interrupts the operation of the wireless remote controller Ensure that there is neither a source of light nor fluorescent lamp near the receiver Also ensure that the receiver is not exposed ...

Страница 3: ...te controllers to operate in 1 room perform address setting for the receiver and the wireless remote controller If setting multiple wired remote controllers in 1 room change the MAIN SUB switch of the receiver 4 3 Setting procedure Setting the receiver Set the wireless address switch SS2 on the PC board according to the table below CAUTION Change the setting so that the internal electronic equipme...

Страница 4: ...pper part on the lower part being careful parts are facing in the correct direction After installation turn on the power and test emergency run button 4 6 Attaching the receiver for wall mounting 1 Wire the indoor unit Connect the P1 and P2 terminals on the rear of the lower part to the P1 and P2 terminals on the indoor unit Neither of the terminals is polarized so it is not important if connectio...

Страница 5: ...he normal display Multiple settings A b When the indoor unit is being operating by outside control cen tral remote controller etc it sometimes does not respond to ON OFF and temperature setting commands from this remote controller Check what setting the customer wants and make the multiple setting as shown below 4 8 Stick the Unit No label on the receiver and the back of the wireless remote contro...

Страница 6: ...ual attached to the outdoor unit if it does not operate 2 Refer to the installation manual attached to the outdoor unit for individual operation system types MODE NO FIRST CODE NO DESCRIPTION OF SETTING 10 0 Filter Contamination Heavy Light Setting for spacing time of display time to clean air filter Setting for when filter contamination is heavy and spacing time of display time to clean air filte...

Страница 7: ... 0505 3P155845 4C EM05A013 FS ...

Отзывы: