4-5. Attaching the receiver (for ceiling installation)

1. Prepare the ceiling for the receiver.

• Open a hole in the ceiling for the receiver. (Use paper pat-

tern printing (9)).

2. Wire the indoor unit and fix the lower part.

• Install the winged bar (10) to the lower part and fit the part 

with the screws (8). Then, wire (field supplied) accordingly.
(Connect the P1 and P2 terminals on the rear of the lower 
part to the P1 and P2 terminals on the indoor unit. The P1 
and P2 terminals have no polarity.)

• Insert the lower part into the opening in the ceiling, first by 

pressing the wings inward to fit the hole and then by 
pushing from the screws (8) until it sits flat on the ceiling.

• Tighten the screws (8) until the lower part is fixed in place.

(Tighten both screws (8) evenly. Overtightening may 
deform the case and possibly make it harder to install the 
upper part.)

• Attach the upper part of receiver (1).

(Install the upper part on the lower part being careful 
parts are facing in the correct direction. After installation, 
turn on the power, and test emergency run button.)

4-6

Attaching the receiver (for wall mounting)

1. Wire the indoor unit.

(Connect the P1 and P2 terminals on the rear of the lower 
part to the P1 and P2 terminals on the indoor unit.
Neither of the terminals is polarized, so it is not important if 
connections are crossed.)

2. Fix the lower part.

• Install the lower part on the control box (field supplied part).

(Select as flat a place as possible to install the lower part. 
Also, be aware of the fact that overtightening the screws (7) 
may deform the case and possibly make it harder to install 
the upper part.)

More than

3-9/16

(Service space)

(Ceiling opening)

4-3/16

(Ceiling opening)

4-9/16

1-15/16

2-5/8

(Length : in.)

Indoor unit

P1
P2

Winged bar (10)

Mounting screw (8)

Transmission wiring

(Field wiring)

Lower part

Emergency run button

Upper part

Lower part

Transmission wiring

P1
P2

Indoor unit

Control box
(Part to be procured in the field)

Control box
(Part to be produced
in the field)

Mounting screw (7)

Lower part

Содержание BRC4C82

Страница 1: ...82 INSTALLATION MANUAL Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should be left with the equipment owner Wireless Remote Controller Kit ...

Страница 2: ... electric shock CAUTION Refer also to the installation manuals attached to the indoor unit and the decoration panel Confirm that the following conditions are satisfied prior to installation Ensure that nothing interrupts the operation of the wireless remote controller Ensure that there is neither a source of light nor fluorescent lamp near the receiver Also ensure that the receiver is not exposed ...

Страница 3: ...te controllers to operate in 1 room perform address setting for the receiver and the wireless remote controller If setting multiple wired remote controllers in 1 room change the MAIN SUB switch of the receiver 4 3 Setting procedure Setting the receiver Set the wireless address switch SS2 on the PC board according to the table below CAUTION Change the setting so that the internal electronic equipme...

Страница 4: ...pper part on the lower part being careful parts are facing in the correct direction After installation turn on the power and test emergency run button 4 6 Attaching the receiver for wall mounting 1 Wire the indoor unit Connect the P1 and P2 terminals on the rear of the lower part to the P1 and P2 terminals on the indoor unit Neither of the terminals is polarized so it is not important if connectio...

Страница 5: ...he normal display Multiple settings A b When the indoor unit is being operating by outside control cen tral remote controller etc it sometimes does not respond to ON OFF and temperature setting commands from this remote controller Check what setting the customer wants and make the multiple setting as shown below 4 8 Stick the Unit No label on the receiver and the back of the wireless remote contro...

Страница 6: ...ual attached to the outdoor unit if it does not operate 2 Refer to the installation manual attached to the outdoor unit for individual operation system types MODE NO FIRST CODE NO DESCRIPTION OF SETTING 10 0 Filter Contamination Heavy Light Setting for spacing time of display time to clean air filter Setting for when filter contamination is heavy and spacing time of display time to clean air filte...

Страница 7: ... 0505 3P155845 4C EM05A013 FS ...

Отзывы: