background image

Wired Remote 

Controller

Installation Manual

MODEL  BRC1H61W/BRC1H61K

+

-

• Be sure to read before conducting the installation of this product, and conduct 

installation according to this manual.

• Refer to this manual together with the installation manual of the indoor unit.

It is possible to perform settings of some functions from  

a smart phone app.

00_CV_EM19A034_IM.indd   1

2020/09/02   15:54:02

Содержание BRC1H61W

Страница 1: ...onducting the installation of this product and conduct installation according to this manual Refer to this manual together with the installation manual of the indoor unit It is possible to perform set...

Страница 2: ...iew of screens 12 Setting screen list 13 Names and Functions 15 Starting up the system 16 Switching the Changeover Master 19 Installer Menu 23 Field Setting 24 R C Setting 31 Installer Password Settin...

Страница 3: ...sult in electric shocks or a fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in the remote controller falling down elec...

Страница 4: ...cause a malfunction of the equipment 4 Where flammable gas may leak where there is carbon fibre or ignitable dust suspensions in the air or where volatile flammables such as thinner or gasoline are h...

Страница 5: ...be seen after the remote controller is installed NOTE 3 11 64 80 5 13 64 5 33 64 13 1 47 64 44 9 32 7 R3 32 2 5 R3 32 2 5 13 64 5 41 64 16 25 1 47 64 44 35 64 13 75 3 11 64 80 5 Back plate Through hol...

Страница 6: ...piece of the back plate according to the following figure After removing a thin piece with a tool such as clippers remove burrs using a file etc a Wiring from top b Wiring from left c Wiring from bot...

Страница 7: ...head wood screws Drywall anchors CAUTION Install the controller on a flat surface only To prevent deformation of the back plate avoid over tightening the installation screws If tightened too much the...

Страница 8: ...maintain a 3 8 inch 10 mm difference between the length of the two conductors Cutting guideline L Wiring outlet L Top 5 5 inch 140 mm Left 4 3 inch 110 mm Bottom 3 5 inch 90 mm Rear No requirements C...

Страница 9: ...8 Top outlet P1P2 P1P2 terminal Rear outlet P1P2 Left outlet P1P2 01_EN_EM19A034_IM indd 8 2020 09 02 15 53 13...

Страница 10: ...top of the controller on the top of the back plate 2 Snap the bottom of the controller into place on the bottom of the back plate 3 Ensure the installation site is dust free before peeling the protec...

Страница 11: ...roller circuit board is attached to the upper casing Be careful not to damage the circuit board and casing when removing the upper casing Do not touch the remote controller circuit board directly with...

Страница 12: ...his button again to turn off the system b Status indicator LED During operation the light ring around the display lights up blue red green Lights up blue Operating Blinks red Error is occurring Lights...

Страница 13: ...enu Information screen Installer menu This screen is a menu for the administrator See the next page for items which can be selected 12 34 A3 01 Unit 00 This screen displays the time and the status of...

Страница 14: ...rrent setting Vertical Airflow Airflow direction 2 setting Depends on current setting Ventilation Mode Ventilation mode setting Depends on current setting Ventilation Rate Ventilation rate setting Adj...

Страница 15: ...t setting Clock Setting Clock setting About Administrator information Admin Password Administrator password setting Installer Password Installer password setting Field Setting Field Setting R C Settin...

Страница 16: ...h Bluetooth Indicates that the controller is communicating with a mobile device for use with the app i Changeover Under Control Displayed when controller is unauthorized to select heating cooling oper...

Страница 17: ...tically start up If it is the first and only controller that is connected to the indoor unit it will automatically get designated as the main controller If there is a second controller it is necessary...

Страница 18: ...RMATION If a sub controller does not display the home screen 2 minutes after its designation turn off the power and check the wiring INFORMATION After re designating a controller the system requires a...

Страница 19: ...ode appears press and hold until 2 appears on the screen When the U8 error code appears press and hold until 1 appears on the screen Result A controller displaying 1 is set as main and a controller di...

Страница 20: ...s the changeover master Depending on the system this function may not be available Possible operation mode selections for a remote controller that is a changeover master or a mode follower Operation m...

Страница 21: ...m When multiple indoor units are connected to the same port of a branch selector unit Give the authority to choose cooling heating or auto to 1 of these remote controllers c c b b c d c b b d d a e f...

Страница 22: ...isite You are in the installer menu You are operating the controller of the indoor unit that you want to release from being the changeover master Home screen 30 C 28 Press and hold button for 5 second...

Страница 23: ...over master This setting is available only when none of the remote control in the system has master control Prerequisite No indoor unit is yet set as the changeover master icon blinking on all control...

Страница 24: ...taller Menu How to enter the Installer menu Installer menu screen Home screen 30 C 28 C Press and hold button for 5 seconds or longer to display the information screen Information screen 12 34 Press i...

Страница 25: ...troller side is impossible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen Mode 20 Unit 00 a b Press or button to select Mode No and press to enter the field...

Страница 26: ...Press or button to select and then press button to set the selection Sub menu screen SW 00 01 a b Press or button select First Code No and then press button a First Code No b Second Code No Sub menu...

Страница 27: ...00 01 Press or button select and then press button to save the setting and return to the previous screen If the setting is not changed select Sub menu screen Mode 20 Unit 00 Press or button move to an...

Страница 28: ...r details about the specific field settings of each type of indoor unit see the installation manual of the indoor unit Field settings that are not available for a connected indoor unit are not display...

Страница 29: ...5 000 hrs Long life filter Approx 2 500 hrs Approx 1 250 hrs Standard filter Approx 200 hrs Approx 100 hrs 1 Long life filter type Setting of filter sign indication time Change setting when Ultra lon...

Страница 30: ...irection range setting Upper Normal Lower 6 Setting the external static pressure Setting according to the connected duct resistance Normal High static pressure Low static pressure For FHYK Normal High...

Страница 31: ...y shipment is set to 01 However for the following cases it is not 01 Airflow direction range setting except Round flow cassette 02 Thermostat sensor in remote controller SPLIT system only 02 Thermosta...

Страница 32: ...e is impossible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen Mode R1 Unit a b Press or button to select Mode No and press to enter the field setting menu a...

Страница 33: ...n SW 13 00 Press or button scroll to the desired First code No and then press button to set the selection Sub menu screen SW 13 00 Press or button to move Second Code No and then press button Sub menu...

Страница 34: ...the installer menu If the setting has been changed the screen may return to the home screen without returning to the installer menu R C setting mode list Mode No FIRST CODE NO Description SECOND CODE...

Страница 35: ...ible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen 0 0 0 0 a b Press or button select Enable Disable and press to perform password enable disable setting a...

Страница 36: ...1 2 3 4 Press or button move to and then press button to return to the installer menu Other Service Settings Group Address Assign the group address and unit number for centralized control The group an...

Страница 37: ...not function properly the external input interlock menu is not available in the installer menu In case a centralised controller is additionally part of the system external input interlock is controlle...

Страница 38: ...at starts as soon as the Delay Timer expires When this timer expires the previous state i e regular setpoint changes to the Default Reset Setting state 0 20 hours 20 hours Reset ON OFF ON OFF Default...

Страница 39: ...rrent active value is kept Window contact logic Window contact B1 Key card contact B2 Time Action Contact closed window open Contact closed key card IN Normal indoor unit operation The unit returns to...

Страница 40: ...Setback function is enabled Setback will work or not Not possible to turn on off the unit with the controller s ON OFF button After the delay timer has expired the reset timer will start counting INFO...

Страница 41: ...Example 1 1 You remove the key card Result The indoor unit continues operating normally until the delay timer expires 2 You open the window before the delay timer expires Result The indoor unit stops...

Страница 42: ...g the window the reset timer will have started counting Closing the window has no influence on the reset timer IF the delay timer HAS NOT expired before closing the window it will expire immediately a...

Страница 43: ...ibution THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNE...

Страница 44: ...1W SQASI TA 20 1972 For model BRC1H61K SQASI TA 20 1973 In Philippines For model BRC1H61W ESD 2022264C For model BRC1H61K ESD RCE 2022819 In Singapore For model BRC1H61W Complies with IMDA Standards N...

Страница 45: ...1H61W Certificate of conformity number 283 CN TT2 For model BRC1H61K Certificate of conformity number 280 CN TT2 DAIKIN Air Conditioning VietNam Joint Stock Company In Australia In New Zealand 01_EN_E...

Страница 46: ...EM19A034 2009 HT 00_CV_EM19A034_IM indd 2 2020 09 02 15 54 02...