Daikin BRC1H51W Скачать руководство пользователя страница 5

6 Operation

Installer and user reference guide

5

BK+S
Wired remote controller
4P513689-1 – 2018.02

Icon

Description

End of demand control. 

Indicates that the system's

energy consumption is no longer being limited, and
that it is no longer running with restricted capacity.

Rotation.

 Indicates that Rotation mode is active.

Setback

. Indicates that the indoor unit is operating

under setback conditions.

Ventilation

. Indicates that a heat reclaim ventilation

unit is connected.

INFORMATION

▪ For  information  on  the  operation  mode  and  ventilation

mode  icons,  see 

"6.2  Operation  mode"  on  page  5

and 

"6.4.1 Ventilation mode" on page 7

 respectively.

▪ Most  icons  are  related  to  things  set  in  the  Daikin

Control  Assistant  app.  For  more  information,  see  the
app.

6

Operation

From  the  home  screen,  press 

  to  enter  the  main  menu.  Use 

and 

 to cycle through the menus. Press 

 again to enter one of

the menus.

INFORMATION

▪ Depending on the type of indoor unit you are operating,

more or less menus may be available.

▪ In  the  main  menu,  the  icon  for  each  menu  reflects  the

current  active  setting  or  mode.  When  operating  the
controller,  the  menu  you  navigate  through  can  look
different from that represented in this manual.

▪ The  controller  only  allows  for  basic  operation  of  the

system.  For  advanced  operation  (setback,  schedule
timer, …), see the Daikin Control Assistant app.

6.1

Setpoint

The setpoint is the target temperature for the Cooling, Heating, and
Auto operation modes.

6.1.1

To set the setpoint

Prerequisite: 

The  active  operation  mode  is  either  'Cooling',

'Heating', or 'Auto'.

1

In the home screen, use 

 and 

 to adjust the setpoint.

Result: 

The indoor unit changes its temperature setpoint.

6.2

Operation mode

The indoor unit can operate in various operation modes.

Icon

Operation mode

Cooling.

 In this mode, cooling will be activated as

required by the setpoint.

Icon

Operation mode

Heating

. In this mode, heating will be activated as

required by the setpoint.

Fan Only

. In this mode, air circulates without heating

or cooling.

Dry

. In this mode, the air humidity will be lowered with

a minimal temperature decrease.

The temperature and fan speed are controlled
automatically and cannot be controlled by the
controller.

Dry operation will not function if the room temperature
is too low.

Ventilation

.In this mode, the space gets ventilated,

but not cooled or heated.

Air Clean

. In this mode, the optional air cleaning unit

operates.

Venti Air Clean.

 Combination of ventilation

and air clean operation.

Auto.

 In Auto mode, the indoor unit automatically

switches between heating and cooling mode, as
required by the setpoint.

INFORMATION

Depending  on  the  indoor  unit,  more  or  less  operation
modes are available.

6.2.1

About the operation modes

INFORMATION

If the indoor unit is a cooling-only model, it can only be set
to run in Cooling, Fan only, or Dry operation mode.

INFORMATION

If  the  operation  mode  changeover  of  an  indoor  unit  is
under  centralised  control  ('changeover  under  centralised
control' status icon blinking in the home screen), then it is
NOT possible to change the operation mode of that indoor
unit.  For  more  information,  see 

"Switch  Cooling/Heating

master" on page 24

.

Cooling

If the outdoor air temperature is high, it can take some time until the
indoor room temperature reaches the setpoint temperature.

If  the  indoor  room  temperature  is  low,  and  the  indoor  unit  is  set  to
run in Cooling, the indoor unit can switch to run in defrost operation
first (i.e. heating operation), this to prevent frost from forming on the
indoor  unit  heat  exchanger,  which  can  decrease  the  system's
cooling capacity. During defrost operation, the system uses a low fan
speed or a gentle wind to prevent the discharge of melt water, while
the controller displays the set fan speed.

Heating

When  running  in  Heating  operation  mode,  the  system  requires  a
longer  time  to  reach  the  setpoint  temperature  than  when  running  in
Cooling operation mode. To make up for this, it is recommended to
let the system start operation in advance by making use of the timer
function.

To  prevent  cold  drafts  and  a  reduction  of  the  system's  heating
capacity,  the  system  can  run  in  the  following  special  heating
operation modes:

Содержание BRC1H51W

Страница 1: ...Installer and user reference guide Wired remote controller English Installer and user reference guide Wired remote controller BRC1H51W BRC1H51K BRC1H51S...

Страница 2: ...Information 12 12 4 1 Information screen 12 12 4 2 Information menu 13 13 Configuration 13 13 1 Installer menu 13 13 1 1 About the installer menu 13 13 1 2 Screen settings 13 13 1 3 Status indicator s...

Страница 3: ...ls In places with temperatures 10 C and 50 C In places where the relative humidity is 95 In places where there is machinery that emits electromagnetic waves Electromagnetic waves may disturb the contr...

Страница 4: ...ng with a mobile device for use with the Daikin Control Assistant app Centralised control Indicates that the system is controlled by central control equipment optional accessory and that control of th...

Страница 5: ...g or cooling Dry In this mode the air humidity will be lowered with a minimal temperature decrease The temperature and fan speed are controlled automatically and cannot be controlled by the controller...

Страница 6: ...unit fan will automatically operate until the indoor temperature of the system rises to a certain level When hot air stays under the ceiling and your feet feel cold it is recommended to include a cir...

Страница 7: ...to confirm Result The indoor unit changes its fan speed and the controller returns to the home screen 6 4 Ventilation INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation un...

Страница 8: ...ntroller only allows for basic operation For advanced operation use the Daikin Control Assistant app 6 5 1 To make a Bluetooth connection Prerequisite You have a mobile device on which the Daikin Cont...

Страница 9: ...nsists of the following stages 1 Determining how you want to route the electrical wiring and nipping away a piece of the rear casing accordingly 2 Mounting the rear casing to the wall 3 Connecting the...

Страница 10: ...included NOTICE When wiring run the wiring away from the power supply wiring in order to avoid receiving electric noise external noise INFORMATION P1 and P2 have no polarity 10 3 2 To connect the ele...

Страница 11: ...ill cause the adapter to go in error The controller gets its power from the indoor unit It will start up as soon as it is connected For the controller to be operable therefore make sure the indoor uni...

Страница 12: ...de c Setpoint temperature Home screen mode is set with remote controller field setting R1 7 Home screen For more information see Remote controller field settings on page 18 Backlight The screen backli...

Страница 13: ...instructions on how to enter the information menu see 13 1 Installer menu on page 13 and Information on page 25 13 Configuration 13 1 Installer menu 13 1 1 About the installer menu In the installer m...

Страница 14: ...ons on how to make field settings see 13 1 4 Field settings on page 14 For an overview of remote controller field settings see Remote controller field settings on page 18 To set status indicator inten...

Страница 15: ...In the field settings tables find the mode numbers that apply to individual indoor units between brackets in the Mode column Second level Setting SW A setting is a settable parameter These are the se...

Страница 16: ...ng component 3 Use and to change the value of that field setting component 4 Press to confirm that value 5 In the first level select to move to the second level 6 In the second level navigate and sele...

Страница 17: ...tenant 02 Thermostat differential if the system contains a remote sensor set the increase decrease increments 1 C 0 5 C 13 23 00 High air outlet velocity set in case of high ceiling applications h 2...

Страница 18: ...ed 1 Standard 1 8 Backlight no operation timer 0 5 seconds 1 10 seconds 2 20 seconds 0 9 Status indicator faintness 0 0 OFF 1 1 2 2 3 3 4 5 5 7 6 9 7 11 8 13 9 15 10 17 11 20 9 10 Backlight faintness...

Страница 19: ...fine groups and or units in the first level and set or release addresses for those groups and or units in the second Address Description First level Group Group A group is a group of indoor units When...

Страница 20: ...utdoor units O U The Group address and AirNet address menu has two levels You define groups and or units in the first level and set and release an address for those groups and or units in the second A...

Страница 21: ...tal input adapter see the installation manual of the digital input adapter In case the digital input adapter does not function properly the external input interlock menu is not available in the instal...

Страница 22: ...ndoor unit s setpoint range and setpoint range limitation 22 C Reset Heat SP Default Reset Setting heating setpoint See indoor unit s setpoint range and setpoint range limitation 22 C INFORMATION When...

Страница 23: ...n the delay timer will start running When the delay timer expires the reset timer will start running When the reset timer expires the previous state is updated to the Default Reset Setting state Examp...

Страница 24: ...a controller displays Then NO status icon The indoor unit connected to that controller is Cooling Heating master a CONSTANT status icon The indoor unit connected to that controller is slave to a Cool...

Страница 25: ...indoor unit is released from its masterhood Result The controllers of all indoor units display a blinking changeover under centralised control icon Information About the information menu In the infor...

Страница 26: ...le cleaning the controller soak the cloth in neutral detergent diluted with water squeeze the cloth tightly and clean the surface Afterwards wipe dry with a dry cloth 14 2 About maintenance When the i...

Страница 27: ...is available on the regional Daikin website publicly accessible The full set of latest technical data is available on the Daikin extranet authentication required 16 1 Connection diagram 16 1 1 Typical...

Страница 28: ...eference guide 28 BRC1H51W K S Wired remote controller 4P513689 1 2018 02 Group control controller digital inputs adapter BRP7A5 0 1 2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 16 1 3 Controller DIII central cont...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...4P513689 1 2018 02 Copyright 2018 Daikin...

Отзывы: