Basic Operation
6
On/Off
nu
K
When the
●
On/Off
button is pressed
again, the system will stop operating
and the operation lamp will turn off.
When the system is stopped while in the heating
*
mode, the fan will continue to operate for
approximately one minute to remove residual
heat from the indoor unit.
Note
To prevent water damage or system failure, do not immediately
●
remove power from the indoor unit following system operation.
Wait at least
fi
ve minutes for the condensate pump to
fi
nish
draining residual water from the unit.
Characteristics of Heat Mode
The system automatically controls the following operating modes to
prevent the reduction of heating capacity and space comfort.
Defrost operation
The system will automatically go into defrost operation to prevent frost
●
accumulation at the outdoor unit and loss of heating capacity.
The indoor unit fan will stop, and “
●
STANDBY ” (Defrost/Hot start) will be
displayed on the remote controller.
The system will return to normal operation usually within six to eight
●
minutes (but not more than 10 minutes).
Hot start
When the system goes into heat mode, the indoor unit fan will stop in
●
order to prevent a cold draft.
(In that case, “ STANDBY ” (Defrost/Hot start) will be displayed on the
remote controller.)
Dry Mode
Preparation
For equipment protection purposes, apply power to the outdoor units at least six hours before
●
starting the operation of the system.
The dry mode may not be selected if the remote controller is master controlled and the
●
system is not already in the cooling mode of operation. (see page 17 for details)
01_EN_3P243520-3E.indd 12
01_EN_3P243520-3E.indd 12
9/11/2012 4:12:41 PM
9/11/2012 4:12:41 PM
Содержание BRC1E72
Страница 21: ...English 19 01_EN_3P243520 3E indd 19 01_EN_3P243520 3E indd 19 9 11 2012 4 12 52 PM 9 11 2012 4 12 52 PM...
Страница 69: ...Fran ais 19 02_FR_3P243520 3E indd 19 02_FR_3P243520 3E indd 19 9 14 2012 3 47 39 PM 9 14 2012 3 47 39 PM...
Страница 117: ...Espa ol 19 03_ES_3P243520 3E indd 19 03_ES_3P243520 3E indd 19 9 14 2012 9 39 22 AM 9 14 2012 9 39 22 AM...
Страница 147: ......
Страница 148: ...3P243520 3E EM12A023 1209 HT 00_CV_3P243520 3E indd 3 00_CV_3P243520 3E indd 3 9 12 2012 9 49 15 AM 9 12 2012 9 49 15 AM...