8
English
Names and Functions
Operation mode
1.
Used to display the current operation
●
mode: Cool, Heat, Vent, Fan, Dry or Auto.
In Auto mode, the actual operation mode
●
(Cool or Heat) will be also displayed.
Operation mode cannot be changed when
●
OFF is displayed.
Operation mode can be changed after
starting operation.
Fan Speed
2.
Used to display the fan speed that is set for
●
the indoor unit.
The fan speed will not be displayed if the
●
connected model does not have fan speed
control functionality.
Setpoint display
3.
Used to display the setpoint for the indoor
●
unit.
Use the Celsius/Fahrenheit item in the
●
main menu to select the temperature unit
(Celsius or Fahrenheit).
Stand by for Defrost/Hot start
4.
“
STANDBY
”
(See page 12.)
If ventilation icon is displayed in this
fi
eld:
Indicates that an energy recovery ventilator
●
is connected.
For details, refer to the Operation Manual
of the ERV.
Message
5.
The following messages may be
displayed.
“This function is not available”
Displayed for a few seconds when an
●
Operation
button is pressed and the indoor
unit does not provide the corresponding
function.
In a remote control group, the message will
●
not appear if at least one of the indoor units
provides the corresponding function.
“Error: Push Menu button”
“Warning: Push Menu button”
Displayed if an error or warning is detected
●
(see page 47)
.
“Time to clean
fi
lter”
“Time to clean element”
“Time to clean
fi
lter & element”
Displayed as a reminder when it is time to
●
clean the
fi
lter or element
(see page 45).
Ventilation
6.
Displayed when a energy recovery
●
ventilator is connected.
Ventilation Mode icon.“
●
AUTO
ERV
ERV
BYPASS
”
These icons indicate the current ventilation
mode (ERV only) (AUTO, ERV, BYPASS).
Air Purify ICON “
●
AIR
PURIFY
”
This icon indicates that the air purifying unit
(option) in operation.
7. display
(See page 18.)
Displayed when the key lock is set.
●
8. display
(See page 28.)
Displayed if the Schedule or Off timer is
●
enabled.
Under Centralized control “
9.
CENTRAL
CONTROL
”
Displayed if the system is under the
●
management of a multi-zone controller
(option) and the operation of the system
through the remote controller is limited.
Changeover controlled by the
10.
master indoor unit “
MASTER
CONTROLLED
”
(VRV only)
Displayed when another indoor unit on the
●
system has the authority to change the
operation mode between cool and heat.
01_EN_3P243520-3E.indd 8
01_EN_3P243520-3E.indd 8
9/11/2012 4:12:38 PM
9/11/2012 4:12:38 PM
Содержание BRC1E72
Страница 21: ...English 19 01_EN_3P243520 3E indd 19 01_EN_3P243520 3E indd 19 9 11 2012 4 12 52 PM 9 11 2012 4 12 52 PM...
Страница 69: ...Fran ais 19 02_FR_3P243520 3E indd 19 02_FR_3P243520 3E indd 19 9 14 2012 3 47 39 PM 9 14 2012 3 47 39 PM...
Страница 117: ...Espa ol 19 03_ES_3P243520 3E indd 19 03_ES_3P243520 3E indd 19 9 14 2012 9 39 22 AM 9 14 2012 9 39 22 AM...
Страница 147: ......
Страница 148: ...3P243520 3E EM12A023 1209 HT 00_CV_3P243520 3E indd 3 00_CV_3P243520 3E indd 3 9 12 2012 9 49 15 AM 9 12 2012 9 49 15 AM...