The wireless remote controller has 2 possible display settings.
The standard setting 

A

 permanently indicates all operational 

items whereas the multi system display setting   indicates 
operations for a limited period of time after execution of 
settings only.
In case the target indoor unit is simultaneously being 
controlled;

 

„

by another unit in group control,

 

„

by a wired remote controller,

 

„

by a centralized remote controller.

the indoor unit sometimes does not respond to ON/OFF and 
temperature setting commands from the wireless remote 
controller.
In order not to confuse the customer with possible 
discrepancies between the wireless remote controller 
display and the actual operation state of the indoor unit, it 
is recommended to set the display on the wireless remote 
controller to 

 in such a control configuration.

Check what setting the customer prefers and adjust the 
display setting accordingly.

Display 
setting

Remote 
controller 
display

Result of the display 
setting in case the 
target indoor unit is 
simultaneously being 
controlled by more than 
1 device

A

: standard All 

operational 
items are 
permanently 
displayed.

In the operation mode 
changeover, temperature 
setting or the like are 
carried out from the 
wireless remote controller, 
the indoor unit rejects the 
instruction.
(Signal receiving sound, 
1 long beep or 3 short 
beeps)
As a result, a display 
discrepancy between 
the operation state of 
the indoor unit and the 
indication on the wireless 
remote controller display 
occurs.

: multi 

system

Operations 
only remain 
displayed 
for a short 
time after 
execution 
of the 
commands.

Since the indications 
on the wireless remote 
controller are turned 
off, a discrepancy such 
as described above no 
longer occurs.

Affix the unit number label

Affix corresponding unit number labels onto both air outlet of 

the decoration panel and onto back of the wireless remote 
controller.

NOTE Set the Unit No. of the receiver and the wireless 

remote controller to be equal. If the settings differ, 
the signal from the remote controller cannot be 
transmitted.

Installation of the transmitter board

(See figure 2)

1  Electrical wiring box cover
2  Transmitter board
3  Shorter wire harness
4  Longer wire harness
5  Clamp
6  Electrical wiring box
7  Plastic spacer

1  Cut off the power supply.
2  Remove the electrical wiring box cover as described in the 

installation manual supplied with the indoor unit.

3  Attach four plastic spacers (7) to the transmitter board (2) 

and install it in the electrical wiring box (6).

4  Connect the shorter wire harness from the X2A connector 

on transmitter board (2) to X24A connector on the printed 
circuit board in the electrical wiring box of indoor unit. Lay 

down the shorter wire harness as shown in the figure 2.

5  When the receiver is installed bring the longer wire 

harness to the electrical wiring box of indoor unit and 
connect it to X1A connector on the transmitter board.

6  Clamp the wire harness by the clamp (5) as shown in the 

figure 2.

Installation of the decoration panel

Install the decoration panel as described in the installation 
manual supplied with the decoration panel.

NOTE Make sure that the wire harness (longer one) from 

the transmitter board is not caught between the 
indoor unit and the decoration panel, and between 
the ceiling and the decoration panel.
The installation process of the receiver depends 
on used decoration panel.

English

01_EN_3P444567-1.indd   3

7/5/2016   11:05:28 AM

Содержание BRC082A41W

Страница 1: ...añol WIRELESS REMOTE CONTROLLER KIT INSTALLATION MANUAL Installation manual Manuel dinstallation Manual de instalación MODELS BRC082A41W BRC082A42W BRC082A42S Manuel dinstallation 00_CV_3P444567 1 indd 1 5 11 2016 13 44 03 ...

Страница 2: ...BRC082A42W 1 1 3 4 1 1 BRC082A42S 1 1 3 4 1 1 Figure 1 X24A X1A X2A 1 7 2 3 6 2 7 5 3 4 2 Figure 2 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING A B C 3 2 4 1 5 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING B D C A 3 2 4 5 1 6 Figure 3 Figure 4 00_CV_3P444567 1_H2 indd 1 6 29 2016 2 25 08 PM ...

Страница 3: ...ow to operate the unit and how to perform maintenance Meaning of caution symbols Failure to observe these instructions properly may result in property damage or personal injury Information classified as NOTE contains instructions to ensure proper use of the equipment Refer also to the installation manual supplied with the indoor unit and the installation manual supplied with the decoration panel T...

Страница 4: ...eceiver and the wireless remote controller If using both a wired remote controller and a wireless remote controller with one indoor unit change the MAIN SUB switch of the transmitter board Setting procedure Setting the transmitter board Set the wireless address switch SS2 on the transmitter board according to the table below Unit No 1 2 3 Wireless address switch SS2 1 2 3 1 2 3 1 2 3 When using bo...

Страница 5: ...he indications on the wireless remote controller are turned off a discrepancy such as described above no longer occurs Affix the unit number label Affix corresponding unit number labels onto both air outlet of the decoration panel and onto back of the wireless remote controller NOTE Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differ the signal fro...

Страница 6: ...e decoration panel Then attach the receiver to the decoration panel Lead the wire harness to the electrical wiring box on the indoor unit and connect it to X1A connector on the transmitter board Remove the screw and input the plastic band Then screw it back The wire harness goes through the plastic band Clamp the wire harness from the receiver to other cables with the clamp Installation of the rec...

Страница 7: ... setting If optional accessories are mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual option handbook for each optional accessory See figure 4 A Mode No B Field Set mode C First code No D Second code No Procedure 1 When in normal mode hold down the button for at least 4 seconds to enter the Field Set mode 2 Select the desired Mode No with th...

Страница 8: ...nged in function of ceiling height H 8 7 8ft 2 7m 8 7 8 H 9 13 16ft 2 7 H 3 0m 9 13 16 H 11 1 2ft 3 0 H 3 5m 1 Selection of air flow direction This setting is to be changed when blocking pad optional kit is used 4 way flow 3 way flow 2 way flow 4 Airflow direction range setting This setting is to be changed when range of swing flap movement needs to be changed Upper Medium Lower NOTE Factory setti...

Страница 9: ...Two dimensional bar code is a manufacturing code 3P444567 1 M15B280 1607 HT 00_CV_3P444567 1 indd 2 5 11 2016 13 44 03 ...

Отзывы: