Si041402EC
Drain Pan Unit / Swing Motor
Removal Procedure
13
7. Drain Pan Unit / Swing Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the drain pan
unit.
When reassembling, make
sure that the hook at the left
side is fitted in the groove.
1
Remove the screw at
the right side of the
drain pan unit.
2
3
Press the right side of
the drain pan unit and
twist the left side.
Remove the drain pan
unit from the indoor
unit.
2. Remove the swing motor.
1
Remove the screw of
the swing motor.
2
Remove the shaft, and
then the swing motor.
(R20084)
Drain pan unit
(R20085)
(R23421)
Shaft
Swing motor
(R20087)