Electrical Box
Si041402EC
8
Removal Procedure
6
Remove the screw, and
then the drip proof
plate.
7
8
Pull out the indoor heat
exchanger thermistor.
Remove the screw and
detach the earth/ground
wire.
Be careful not to lose the clip
for the thermistor.
9
10
Remove the screw of
the electrical box.
Lift up and pull the
electrical box.
11
Unfasten the hook at
the top by pressing it
from above and remove
the electrical box.
Step
Procedure
Points
Drip proof plate
(R20068)
Indoor heat
exchanger
thermistor
Earth/ground
wire
(R20983)
Clip
(R11234)
Electrical box
(R20070)
(R20071)
Hook