Troubleshooting
Si04-402A
90
Service Diagnosis
Troubleshooting
Check No.5
Refer to P.105
Check No.6
Refer to P.106
Check No.11
Refer to P.109
Correct.
Reconnect.
Replace the four way valve
coil.
Replace the outdoor unit
PCB.
Reconnect in position.
Replace a defective
thermistor.
Refer to the refrigerant line
check procedure.
Replace the four way valve
(defective or dust-clogged).
(R3040)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Four way valve coil
disconnected (loose)?
YES
YES
NO
Functioning
NO
C
heck No.
11
Check the refrigerant line.
Malfunctioning
l
Insufficient gas
l
Water mixed
l
Stop valve defective
Harness out of connector?
NO
YES
Disconnect the
harness from
the connector.
Resistance between
harnesses about
3k
Ω
±0.5k
Ω
?
Malfunctioning
Functioning
C
heck No.
5
Check the four way valve
switching output.
YES
NO
Any thermistor disconnected?
Malfunctioning
Functioning
C
heck No.
6
Check the thermistors.
Check the continuity of the four
way valve coil and harness.
Содержание ARXG25CVMB
Страница 1: ...Inverter Pair Wall Mounted Type C Series Applied Models z z z zInverter Pair Heat Pump Si04 402A ...
Страница 23: ...Printed Circuit Board Connector Wiring Diagram Si04 402A 14 Printed Circuit Board Connector Wiring Diagram ...
Страница 167: ...Outdoor Unit Si04 402A 158 Removal Procedure When reassembling make sure to fit the hook Step Procedure Points ...
Страница 181: ...Outdoor Unit Si04 402A 172 Removal Procedure ...
Страница 185: ...Others Si04 402A 176 Others ...
Страница 189: ...Wiring Diagrams Si04 402A 180 Appendix ...