Instruction
Si04-402A
50
System Configuration
9
■
To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button” to
set the clock to the present time.
Holding down “
”
or “
” button rap-
idly increases or decreases the time dis-
play.
3. Press “CLOCK button”.
blinks.
NOTE
■
■
■
■
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
■
■
■
■
Please note
• The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
• Use the air conditioner in the following conditions.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
1.3
2
Recommended temperature setting
For cooling:26
°
C – 28
°°°°
C
For heating:20
°
C – 24
°
C
Mode
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature: 10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature: –15 to 21 °C
Indoor temperature: 10 to 30 °C
• A safety device may work to stop the operation.
DRY
Outdoor temperature: 10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
Содержание ARXG25CVMB
Страница 1: ...Inverter Pair Wall Mounted Type C Series Applied Models z z z zInverter Pair Heat Pump Si04 402A ...
Страница 23: ...Printed Circuit Board Connector Wiring Diagram Si04 402A 14 Printed Circuit Board Connector Wiring Diagram ...
Страница 167: ...Outdoor Unit Si04 402A 158 Removal Procedure When reassembling make sure to fit the hook Step Procedure Points ...
Страница 181: ...Outdoor Unit Si04 402A 172 Removal Procedure ...
Страница 185: ...Others Si04 402A 176 Others ...
Страница 189: ...Wiring Diagrams Si04 402A 180 Appendix ...